Anritsu 68017C Synthesized CW Generator, 0.01 – 8.4 GHz

Anritsu 68017C,CW generator supporting 10 MHz to 8.4 GHz frequency range. Offers excellent signal quality and stability for RF circuit testing, wireless development, and production verification.

Model
Anritsu 68017C
Calibration
Available on request
Price
$17,570
Status
In stock
RFQ ref
68017C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 68017C is a synthesized CW generator delivering precision RF signal generation across 0.01 to 8.4 GHz. Built for RF circuit testing, wireless development, and production verification, it combines ultra-low phase noise, flexible modulation, and advanced sweep capabilities with GPIB remote control. Engineers rely on it for applications demanding signal purity, frequency agility, and stable leveled output across demanding test environments.


Technical Specifications

Frequency Range: 0.01 to 8.4 GHz (10 MHz to 8.4 GHz) Output Power:

  • Maximum: +17 dBm

  • Minimum: –125 dBm

  • Guaranteed leveled power to 20 GHz: +17 dBm Signal Purity:

  • SSB phase noise: –107 dBc at 10 kHz offset from 10 GHz

  • Non-harmonic spurious: –100 dBc Frequency Resolution: 0.1 Hz (Option 11); standard step size 1 kHz across full range Switching Time: <5 ms for <100 MHz sweep steps


Key Features Modulation & Waveforms:



  • Internal AM, FM, phase, and pulse modulation

  • Seven internal modulating waveforms including Gaussian noise

  • User-downloadable arbitrary modulation waveforms

  • Doublet, triplet, and quadruplet pulse generation for RADAR blind spot testing

  • Swept delay for moving target simulation

  • Simultaneous synchronized modulations across entire frequency range Sweep Modes:

  • CW or step sweep operation

  • Step sweep: 1 ms to 99 seconds per step

  • Fixed rate sweep: 20 ms to 99 seconds per step

  • Manual, alternate, logarithmic, and digital frequency/power sweep modes Control & Integration:

  • GPIB (IEEE 488) with optional SCPI programmability (Option 19)

  • TTL end-of-sweep input/output signals

  • External or internal pulse modulation parameter control


Optional Enhancements Option 15A adds high-power RF output (2–20 GHz range). Option 16 provides ovenized 10 MHz reference with <5 × 10⁻¹⁰ /day stability. Option 17B removes front panel for remote operation.


Typical Applications RF subsystem characterization, receiver sensitivity testing, transmitter verification, component S-parameter measurements, and radar signal simulation.

Specifications

ParameterValue
Frequency Range0.01 to 8.4 GHz | Power Range (dBm): –125 dBm to +17 dBm

Anritsu 68017C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 68017C. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 68017C faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 68017C price

This Anritsu 68017C is listed at $17,570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 68017C calibration cost

NIST-traceable calibration for the Anritsu 68017C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →