Anritsu 68347C Synthesized High Performance Signal Generator, 10 MHz – 20 GHz

Anritsu 68347C,"High-performance signal generator delivering 10 MHz to 20 GHz signals with exceptional stability. Ideal for RF and microwave component testing. Offers wide power range, fine frequency resolution, and programmable control. Designed to support complex signal simulations in R&D labs and automated test setups."

Model
Anritsu 68347C
Calibration
Available on request
Price
$5,479
Status
In stock
RFQ ref
68347C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 68347C is a synthesized signal generator spanning 10 MHz to 20 GHz, engineered for RF and microwave component testing in ATE and R&D environments. It delivers +17 dBm guaranteed leveled power across its full range with 1 kHz frequency resolution and 0.01 dB output power steps. The instrument combines ultra-low SSB phase noise (-107 dBc at 10 kHz offset from 10 GHz), sub-5 ms switching time, and advanced modulation flexibility

AM, FM, pulse, phase, and scan modes with seven internal waveforms plus user-defined options.


Pulse modulation supports radar blind spot simulation, recovery time testing, and moving target emulation. Sweep capabilities span digital frequency and power sweep, analog sweep, step sweep with up to 10,000 phase-locked steps adjustable from 1 ms to 99 seconds per step, logarithmic sweep, and alternate sweep between two ranges. List mode stores up to 4 tables with 2000 non-sequential frequency/power sets.


Optional 110 dB step attenuator (Option 2A) extends dynamic range to -120 dBm minimum output; Option 11 provides 0.1 Hz frequency resolution. Internal noise generators (Gaussian and uniform) support controlled jitter in digital receiver testing. Output power flatness remains within 4.0 dB (0.01–0.05 GHz) and 2.0 dB (0.05–20 GHz) typical.


Less than 5 ms switching time enables rapid frequency and power transitions across demanding automated test sequences.


Technical Specifications



  • Frequency Range: 10 MHz to 20 GHz

  • Frequency Resolution: 1 kHz standard; 0.1 Hz with Option 11

  • Output Power: +17 dBm guaranteed leveled power to 20 GHz; +13 to -15 dBm typical; -120 dBm minimum with attenuator; -125 dBm minimum power; +11 dBm with step attenuator

  • Output Power Steps: 0.01 dB

  • Output Power Flatness: 4.0 dB (0.01–0.05 GHz); 2.0 dB (0.05–20 GHz) typical

  • SSB Phase Noise: -107 dBc at 10 kHz offset from 10 GHz

  • Switching Time: Less than 5 ms

  • Step Attenuator (Option 2A): 110 dB range in 10 dB steps


Key Features



  • AM, FM, phase, pulse, and scan modulation with seven internal waveforms

  • Pulse modulation for radar simulation, blind spot testing, recovery time analysis, and moving target emulation

  • Digital and analog frequency sweep; digital power sweep

  • Step sweep: 1 to 10,000 steps, 1 kHz resolution, 1 ms to 99 seconds per step

  • Log sweep with frequency-dependent step scaling

  • Alternate sweep mode between two independent ranges

  • Manual stepped sweep with phase-locked adjustment

  • List mode: 4 tables × 2000 frequency/power sets

  • Gaussian and uniform noise generators for jitter simulation

  • Dwell time: 20 ms to 99 seconds per step

  • Ultra-low spurious signals


Typical Applications



  • RF and microwave component characterization

  • Radar receiver and transceiver testing

  • Digital receiver validation with controlled jitter

  • Automated test equipment integration

  • Phase-locked frequency and power stepping


Compatibility & Integration Designed for ATE environments and laboratory R&D with automated control interfaces supporting complex signal sequences.

Specifications

ParameterValue
Frequency Range10 MHz to 20 GHz | Power Range (dBm): '+17 dBm to -120 dBm

Anritsu 68347C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 68347C. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 68347C faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 68347C price

This Anritsu 68347C is listed at $5,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 68347C calibration cost

NIST-traceable calibration for the Anritsu 68347C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →