Anritsu 69047A Synthesized CW Generator, 10 MHz – 20 GHz

Anritsu 69047A,"Microwave signal generator delivering stable continuous wave signals from 10 MHz to 20 GHz. Designed for reliable RF performance with precise output control and low phase noise. Ideal for laboratory testing, RF subsystem evaluation, and automated test setups. Offers user-friendly interface and remote programmability through standard communication protocols."

Model
Anritsu 69047A
Calibration
Available on request
Price
$10,480
Status
In stock
RFQ ref
69047A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69047A is a synthesized continuous wave generator delivering stable RF signals from 10 MHz to 20 GHz with maximum output power of +13 dBm and phase noise performance of -107 dBc/Hz at 10 kHz offset. Built for precision RF applications, it combines ultra-low phase noise with flexible modulation

AM, FM, pulse, and phase - plus arbitrary waveform capability and advanced sweep modes for laboratory testing, RF subsystem characterization, and automated test equipment integration.


Technical Specifications

Frequency Performance

  • Frequency range: 10 MHz to 20 GHz

  • Frequency resolution: 100.0 mHz

  • Phase-locked capability with high resolution Output Power

  • Maximum output power: +13 dBm

  • Minimum output power: -125 dBm

  • Output power (step attenuator): +11.0 dBm

  • Output power (electronic step attenuator): +3.0 dBm

  • Output impedance: 50 Ohm

  • Output level switching time: 20 ms

  • Output accuracy: 2 dB Phase Noise

  • SSB phase noise: -107 dBc at 10 kHz offset from 10 GHz

  • Minimum SSB noise floor: -105 dBc/Hz

  • Maximum SSB noise: -66 dBc/Hz Modulation

  • Modes: AM, FM, Pulse, Phase, and user-downloaded arbitrary modulation

  • FM sensitivity: ±10 kHz per volt to ±20 MHz per volt (locked and narrow modes); ±100 kHz per volt to ±100 MHz per volt (wide mode)

  • FM deviation: ±100 MHz (wide), ±10 MHz (narrow), or lesser of ±10 MHz or rate × 300 (locked)

  • Pulse modulation: Doublet, triplet, or quadruplet pulses; externally or internally driven

  • TTL-compatible external pulse drive input


Key Features



  • Ultra-low phase noise across the full 10 MHz–20 GHz spectrum

  • Wide dynamic range from -125 dBm to +13 dBm

  • Flexible FM bandwidth: DC to 100 Hz (unlocked wide), DC to 500 kHz (unlocked narrow), 1 kHz to 500 kHz (locked)

  • Advanced pulse modulation for radar blind-spot testing

  • CW, step, alternate, analog, and power sweep modes

  • Remote programmability via standard communication protocols


Typical Applications



  • RF component and subsystem validation

  • Radar and microwave system testing

  • Automated production test setups

  • Phase noise characterization

  • Modulation fidelity measurement


Compatibility & Integration Standard 50 Ohm output, TTL-compatible external modulation inputs, and programmable interface enable straightforward integration into multi-instrument test systems and ATE platforms.

Specifications

ParameterValue
Frequency Range10 MHz to 20 GHz | Power Range (dBm): '-125 dBm to +13 dBm

Anritsu 69047A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69047A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69047A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69047A price

This Anritsu 69047A is listed at $10,480. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69047A calibration cost

NIST-traceable calibration for the Anritsu 69047A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents