Anritsu 69075A Synthesized CW Generator, 0.5 – 50 GHz
Anritsu 69075A,"Synthesized CW signal generator covering 0.5 to 50 GHz. Designed for RF engineers needing reliable and clean signal sources."
- Model
- Anritsu 69075A
- Calibration
- Available on request
- Price
- $31,530
- Status
- In stock
- RFQ ref
- 69075A
This unit
The Anritsu 69075A Synthesized CW Generator delivers phase-locked continuous wave signal generation across 0.5–50 GHz with precise frequency control and exceptional stability. Built for RF and microwave system characterization, it supports twenty independent presettable frequencies (F0–F9, M0–M9) and multiple sweep modes, enabling rapid frequency switching and sophisticated test automation.
Technical Specifications
Frequency Control & Time Base- Frequency range: 0.5–50 GHz
- Standard resolution: 1 kHz (Option 11: 0.1 Hz)
- Frequency accuracy: Tied to internal or external 10 MHz time base
- Internal time base aging: <2 × 10⁻⁸/day (Option 16: <5 × 10⁻¹⁰/day)
- Internal time base temperature stability: <2 × 10⁻⁸/°C (0–55°C); Option 16: <2 × 10⁻¹⁰/°C
- External 10 MHz reference input: 0 to +10 dBm, 50 Ω, BNC connector
- 10 MHz reference output: 0.5 V p-p into 50 Ω, AC coupled, rear panel BNC
- Frequency switching time: <40 ms typical maximum to within 1 kHz Sweep Capabilities
- Phase-locked step sweep: 1 kHz to full range sweep width; 1–10,000 steps
- Step dwell time: 1 ms to 99 seconds
- Sweep step switching: <15 ms + 1 ms/GHz of step size, or <40 ms (whichever is less)
- Alternate sweep mode: Two independent sweep ranges with selectable power levels
- Manual sweep mode: User-defined stepped, phase-locked frequency adjustments
Key Features
- Twenty independent CW frequency presets for rapid test sequence execution
- Phase-locked frequency switching ensures signal coherence across test points
- Selectable 1 kHz or 0.1 Hz resolution for fine frequency tuning
- Optional ultra-stable time base (Option 16) for long-duration measurements
- External 10 MHz reference input for synchronization with external standards
Typical Applications
- Component and subsystem RF characterization
- Frequency response measurements across microwave bands
- Phase-coherent multi-frequency testing
- Automated test sequences with preset frequency switching
Compatibility & Integration The 69075A accepts external 10 MHz reference signals (0 to +10 dBm) on a rear panel BNC connector, enabling integration with atomic clocks and precision timing systems. External reference input automatically overrides internal time base when applied.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.5–50 GHz | Power Range (dBm): 0 to +10 dBm (external 10 MHz reference input) | Voltage / Current Range: 0.5 V p-p (10 MHz reference output) |
Anritsu 69075A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 69075A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 69075A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 69075A price
This Anritsu 69075A is listed at $31,530. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 69075A calibration cost
NIST-traceable calibration for the Anritsu 69075A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →