Anritsu 69237A Synthesized Signal Generator

Anritsu 69237A Synthesized Signal Generator,Provides flexible signal output for multi-band applications, offering essential capabilities for aerospace and RF component testing with consistent amplitude accuracy.

Model
Anritsu 69237A
Calibration
Available on request
Price
$16,570
Status
In stock
RFQ ref
69237A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69237A Synthesized Signal Generator delivers flexible, multi-band signal output for aerospace and RF component testing. It has CW stimulus, swept measurements, and modulation capabilities across broad frequency coverage. The instrument combines ultra-low phase noise with user-defined waveform support and synchronized modulation, making it suitable for demanding signal simulation and component characterization tasks.


Technical Specifications

-# Frequency & Output Power

  • Frequency coverage from 0.01 GHz to 20.0 GHz with optional 0.1 Hz resolution

  • Maximum output power: +17 dBm

  • Minimum output power: −125 dBm

  • SSB phase noise: −100 dBc at 10 kHz offset from 10 GHz -# Modulation & Waveform Generation

  • Internal AM, FM, ØM, and pulse modulation

  • 7 internal modulating waveforms including Gaussian noise

  • Support for user-defined arbitrary waveforms and user-downloadable complex modulation

  • Doublet, triplet, and quadruplet pulse configurations for RADAR blind spot testing

  • Simultaneous synchronized modulations across the entire frequency range -# Sweep Capabilities

  • CW and step sweep modes

  • Variable dwell time: 1 ms to 99 seconds for step sweep

  • Step sweep switching time: less than 15 ms + 1 ms/GHz step size, or less than 40 ms (typical maximum)

  • Discrete CW frequencies with broad and narrow band step sweep options


Key Features



  • Consistent amplitude accuracy for multi-band applications

  • Analog, step, and manual sweep capability

  • Flexible signal generation for complex test scenarios

  • Output level flatness correction support


Typical Applications



  • Aerospace component testing and RF characterization

  • Swept frequency measurements

  • Complex signal simulation and stimulus

  • RADAR and pulse modulation testing

Specifications

ParameterValue
Frequency Range0.01 GHz to 20.0 GHz | Power Range (dBm): −125 dBm to +17 dBm

Anritsu 69237A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69237A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69237A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69237A price

This Anritsu 69237A is listed at $16,570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69237A calibration cost

NIST-traceable calibration for the Anritsu 69237A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →