Anritsu 69337A Synthesized Sweep/Signal Generator, 2 – 20 GHz
Anritsu 69337A Synthesized Sweep/Signal Generator,Provides wideband signal generation from 2 to 20 GHz with precise frequency control and high reliability. Ideal for signal simulation, automated test systems, and advanced RF component testing.
- Model
- Anritsu 69337A
- Calibration
- Available on request
- Price
- $8,279
- Status
- In stock
- RFQ ref
- 69337A
This unit
The Anritsu 69337A is a synthesized sweep/signal generator delivering precision wideband signal generation across 2–20 GHz. Built for demanding RF applications, it combines ultra-low phase noise, wide dynamic range output control, and flexible sweep modes to support signal simulation, component characterization, and integration into automated test systems. Multiple modulation types, programmable step sweeping, and high-speed frequency switching enable rapid prototyping and manufacturing test workflows.
Technical Specifications
Frequency Range: 2 GHz to 20 GHzFrequency Resolution: 1 kHz standard; 0.1 Hz with Option 11
SSB Phase Noise: −100 dBc/Hz at 10 kHz offset from 10 GHz
Output Power Range: −125 dBm to +17 dBm Sweep Modes:
- Analog, step, and manual sweep
- Sweep width: 1 kHz to full frequency range (0.1 Hz minimum with Option 11)
- Step sweep: 1 to 10,000 steps; dwell 1 ms to 99 seconds
- Frequency switching: Typically <15 ms + 1 ms/GHz step size, or <40 ms (whichever is less)
- Alternate sweep between two independent ranges
- Sweep time: 30 ms to 99 seconds
- Sweep accuracy: ±30 MHz or ±2 MHz width (whichever is less) at ≤50 MHz/ms sweep speed Modulation: Internal AM, FM, phase modulation, and pulse modulation. User-downloadable complex modulation. Seven internal modulating waveforms including Gaussian noise and arbitrary user-defined waveforms. Frequency Stability: Phase-locked to internal or external 10 MHz time base; accuracy dependent on selected time base.
Key Features
- Single coaxial RF output
- Internal/external 10 MHz time base input/output for synchronization
- Low spurious signal levels
- SCPI command programming support
- Software driver compatibility for standard programming environments
Typical Applications
- Signal simulation and RF component testing
- Local oscillator replacement
- Swept measurements and network analysis
- Automated test equipment (ATE) integration
- Manufacturing and RF development environments
Compatibility & Integration The 69337A supports SCPI commands and integrates into existing test frameworks via software drivers, enabling straightforward incorporation into test automation suites and development workflows.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2 GHz to 20 GHz | Power Range (dBm): −125 dBm to +17 dBm |
Anritsu 69337A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 69337A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 69337A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 69337A price
This Anritsu 69337A is listed at $8,279. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 69337A calibration cost
NIST-traceable calibration for the Anritsu 69337A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →