HP / Agilent 81101A Pulse Generator, 50 MHz
The HP / Agilent 81101A is a 50 MHz pulse generator, designed for versatile signal generation in electronics testing and research. It delivers precise control over pulse parameters, offering adjustable pulse width, amplitude, and delay. Ideal for simulating digital signals and testing the response of electronic circuits.
- Model
- HP / Agilent 81101A
- Calibration
- Available on request
- Price
- $4,508
- Status
- In stock
- RFQ ref
- 81101A
This unit
The HP/Agilent 81101A is a single-channel pulse generator delivering precision signal generation across a 1 mHz to 50 MHz frequency range. It has independent control over pulse width, amplitude, delay, and transition time with timing resolution to 5 ps and frequency accuracy of 0.01%. The instrument generates output amplitudes up to 10 Vpp into 50 Ω or 20 Vpp into 1 kΩ load impedance, with selectable output impedance and level accuracy of ±(3% + 75 mV) into 50 Ω. Period range extends from 20 ns to 999.5 s, while pulse width is continuously adjustable from 1.25 ns to (period - 1.25 ns) across multiple resolution modes. Transition times range from 5 ns to 200 ms with 10/90 accuracy of ±10% ±200 ps. The graphical display and full SCPI programmability via HP-IB enable remote operation and integration into automated test systems. Glitch-free timing with repeatability typically four times better than stated accuracy ensures reliable pulse generation for circuit validation and digital signal simulation.
Technical Specifications Timing & Frequency
Frequency range: 1 mHz to 50 MHz
Frequency accuracy: 0.01%
Period range: 20 ns to 999.5 s
Timing resolution: 5 ps (best case)
Pulse width range: 1.25 ns to (period - 1.25 ns) at 5 ps resolution
Pulse width accuracy: ±5% ±250 ps (valid to 5.5 Vpp)
Transition time range (10/90): 5 ns to 200 ms
Transition time accuracy: ±10% ±200 ps
Delay accuracy: ±5% ±1 ns
Double pulse delay accuracy: ±5% ±500 ps Output Specifications
Output amplitude into 50 Ω: 100 mVpp to 10.0 Vpp
Output amplitude into 1 kΩ: 200 mVpp to 20.0 Vpp
Output impedance: Selectable 50 Ω or 1 kΩ
Level accuracy into 50 Ω: ±(3% + 75 mV)
Level accuracy into 1 kΩ: ±(3% + 150 mV)
Level window into 50 Ω: −10.0 V to +10.0 V
Level window into 1 kΩ: −20.0 V to +20.0 V
Level settling time: 30 ns typical General
Output channels: 1
Interface: SCPI programmable via HP-IB
Display: Graphical
Power: 100–240 VAC ±10%, 50–60 Hz; 300 VA max
Operating temperature: 0°C to 55°C
Dimensions: 8.9 cm height, full rack width
Key Features
Continuously variable timing parameters - period, delay, and pulse width - without glitches or dropouts
Multiple pulse width resolution modes down to 1.25 ns for fine control
Programmable transition time from 5 ns to 200 ms with asymmetric leading/trailing edge control
Load compensation for non-50 Ω impedances
Timing repeatability typically 4× better than accuracy specifications
Typical Applications
Digital circuit testing and characterization
Protocol signal simulation and validation
Device switching and edge-triggering analysis
High-speed logic and timing verification
Compatibility & Integration Full SCPI command compatibility with the 81100 family enables straightforward integration into existing test platforms and automated measurement systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1 mHz to 50 MHz | Voltage / Current Range: 100 mVpp to 10.0 Vpp (50 Ω) |
HP / Agilent 81101A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 81101A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 81101A price
This HP / Agilent 81101A is listed at $4,507.9. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 81101A calibration cost
NIST-traceable calibration for the HP / Agilent 81101A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →