HP 83592B 10MHz to 20GHz Signal Generator
HP RF Signal Sources. Frequency Range: 10 MHz to 20 GHz, Sensitivity: 20 MHz/V (FM mode).
- Model
- HP 83592B
- Calibration
- Available on request
- Price
- $13,480
- Status
- In stock
- RFQ ref
- 83592B
This unit
The HP 83592B is a plug-in signal generator module for the HP 8350A/B sweep oscillator mainframe, delivering continuous coverage from 10 MHz to 20 GHz. This broadband coaxial swept frequency source provides precise frequency generation, excellent signal quality, and dynamic output power control across four internal frequency bands. It serves multiple roles: scalar network analysis, local oscillator support, and general-purpose signal sourcing for telecommunications, aerospace, and defense applications requiring high-frequency test signals.
Technical Specifications
Frequency Performance- Frequency Range: 10 MHz to 20 GHz
- Internal Bands: 0.01–2.4 GHz, 2.3–7.0 GHz, 6.9–13.5 GHz, 13.4–20.0 GHz
- CW Accuracy (25 ±5°C): ±5 MHz across 0.01–20 GHz
- Sweep Mode Accuracy (sweep times > 100 ms): ±15 MHz across 0.01–20 GHz
- Temperature Stability: ±200 kHz/°C (typical)
- Time Stability (10-minute period): ±100 kHz (typical)
- Residual FM (10 Hz–10 kHz bandwidth): 12 dB (>9 dB with Option 002) Spectral Purity
- Harmonics: <-20 dBc
- Subharmonics: <-20 dBc
- Nonharmonic Spurious: -50 to -55 dBc depending on band Modulation Capabilities
External AM: 100 kHz frequency response, 15 dB range, 1 dB/V sensitivity, 10 kΩ input impedance, 15 V maximum input.
External FM: DC to 100 Hz deviation ±75 MHz; 100 Hz to 1 MHz ±7 MHz; 1–2 MHz ±5 MHz; 2–10 MHz ±1 MHz. Sensitivity -20 MHz/V (FM mode), -6 MHz/V (phase-lock mode). 2 kΩ input impedance.
Pulse Modulation: TTL-compatible pulse input. Rise/fall times 50 ns (0.01–2.5 GHz), 10 ns (2.5–20 GHz).
Key Features
- Four internal frequency bands for optimized performance across the entire range
- Selectable 70 dB step attenuator option (Option 002) for extended dynamic range
- TTL-compatible pulse modulation with fast switching times
- External AM and FM modulation inputs for flexible signal conditioning
- Excellent spectral purity with controlled harmonic and nonharmonic content
Compatibility & Integration Designed exclusively as a plug-in module for HP 8350A/B sweep oscillator mainframes. Integration with the mainframe controller enables swept and modulated signal generation for network analysis and frequency-dependent measurements.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 20 GHz | Power Range (dBm): '-72 dBm to +13 dBm | Voltage / Current Range: 10 kΩ input impedance (FM, 15 V maximum input (AM modulation) |
HP 83592B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP 83592B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP 83592B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP 83592B price
This HP 83592B is listed at $13,480. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP 83592B calibration cost
NIST-traceable calibration for the HP 83592B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →