HP / Agilent 83650B Synthesized Swept-Signal Generator, 0.01 – 50 GHz ,+10 dBm calibrated
HP / Agilent RF Signal Sources. Frequency Range: ** 0.01 GHz to 50 GHz (10 MHz to 50 GHz), Accuracy: ±1 dB (typical).
- Model
- HP / Agilent 83650B
- Calibration
- Available on request
- Price
- $16,500
- Status
- In stock
- RFQ ref
- 83650B
This unit
The HP/Agilent 83650B is a synthesized swept-signal generator delivering precision RF signal generation from 0.01 GHz to 50 GHz with calibrated output power of +10 dBm. Built for microwave component characterization, system integration testing, and high-frequency validation across communications, radar, and satellite applications, the instrument combines fast frequency switching with excellent spectral purity and stable power delivery.
Technical Specifications Frequency Range: 0.01 GHz to 50 GHz (10 MHz to 50 GHz) Output Power:
Calibrated output power: +10 dBm
Standard minimum settable output power: -20 dBm
Option 001 minimum settable output power: -110 dBm
Maximum leveled output power reduced by 1.5 dB up to 20 GHz; 2 dB above 20 GHz; 2.5 dB above 40 GHz Power Accuracy & Stability:
Power accuracy: ±1 dB (typical)
Power repeatability: ±0.1 dB (typical)
Temperature stability: 0.01 dB/°C (typical) Spectral Purity:
Harmonics: ≥50 dB below carrier (2.0–26.5 GHz); ≥40 dB below carrier (above 26.5 GHz)
Single-sideband phase noise: -70 dBc/Hz @ 100 Hz offset (10 MHz to <7 GHz); -78 dBc/Hz @ 1 kHz offset (10 MHz to <7 GHz); -86 dBc/Hz @ 10 kHz offset (10 MHz to <7 GHz); -107 dBc/Hz @ 100 kHz offset (10 MHz to <7 GHz) Switching Performance:
Switching time (without attenuator change): 10 ms (typical)
Frequency switching speed: <100 µs (typical)
Step/list sweep mode: 5 ms (typical)
Key Features
Frequency range spanning 0.01–50 GHz enables coverage across X-, Ku-, K-, Ka-, and W-band applications
Fast frequency switching under 100 µs supports rapid test sequences and automated measurement routines
Precise power control with ±1 dB accuracy and ±0.1 dB repeatability after user calibration
Excellent phase noise performance across multiple offset frequencies ensures high-fidelity signal generation
Internal pulse modulation with 15 ns minimum pulse width and 10 ns rise/fall time (400 MHz and above)
Typical Applications
Component characterization and acceptance testing
System integration and RF validation
Radar and satellite communication subsystem testing
Microwave filter and amplifier measurements
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.01 GHz to 50 GHz | Power Range (dBm): '-110 dBm to +10 dBm |
HP / Agilent 83650B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83650B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83650B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83650B price
This HP / Agilent 83650B is listed at $16,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83650B calibration cost
NIST-traceable calibration for the HP / Agilent 83650B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →