Agilent / Keysight 8648D Synthesized RF Signal Generator, 9 kHz to 4000 MHz
The Agilent/Keysight 8648D is a synthesized RF signal generator that delivers reliable performance and essential features for a variety of applications. Covering a frequency range of 9 kHz to 4000 MHz, it provides calibrated output power and versatile modulation capabilities.
- Model
- Agilent / Keysight 8648D
- Calibration
- Available on request
- Price
- $1,794
- Status
- In stock
- RFQ ref
- 8648D
This unit
The Agilent/Keysight 8648D is a synthesized RF signal generator covering 9 kHz to 4000 MHz with calibrated output power, precise frequency control, and versatile modulation capabilities. Designed for high-volume manufacturing, semi-automated receiver testing, and general-purpose signal sourcing, the 8648D delivers measurement consistency and repeatability across diverse test environments.
Technical Specifications
Frequency Performance- Operating range: 9 kHz to 4000 MHz
- Settable resolution: 0.001 Hz increments
- Display resolution: 10 Hz
- Frequency accuracy (standard): ±3 × 10⁻⁶ × carrier frequency
- Frequency accuracy (Option 1E5 High Stability): ±0.15 × 10⁻⁶ × carrier frequency
- Aging rate (standard): <±2 ppm/year
- Aging rate (Option 1E5): <±0.1 ppm/year
- Temperature stability (standard): <±1 ppm
- Temperature stability (Option 1E5): <±0.01 ppm
- Frequency switching: <75 ms below 1001 MHz; <100 ms at 1001 MHz and above Output Power
- Range below 2500 MHz: +13 dBm to -136 dBm
- Range below 4000 MHz: +10 dBm to -136 dBm
- Output impedance: 50 ohms nominally
- Reverse power protection: 50 watts (≤2000 MHz); 25 watts (≤4000 MHz)
- Power accuracy below 2500 MHz: ±1.0 dB
- Power accuracy below 3200 MHz: ±1.5 dB
- Power accuracy below 4000 MHz: ±2.0 dB Spectral Purity
- Harmonics (≤+4 dBm output): <-30 dBc
- Subharmonics below 1001 MHz: <-60 dBc
- SSB phase noise at 500 MHz (20 kHz offset): <-120 dBc/Hz
- SSB phase noise at 1000 MHz (20 kHz offset): <-116 dBc/Hz
- SSB phase noise at 2000 MHz (20 kHz offset): <-110 dBc/Hz Output Characteristics
- SWR below 2500 MHz (output <-6 dBm): <1.5:1
- SWR below 4000 MHz (output <-6 dBm): <2.0:1
Key Features
- High-precision frequency synthesis with 0.001 Hz tuning resolution
- Optional 1E5 timebase reduces aging to ±0.1 ppm/year and improves temperature stability to ±0.01 ppm
- Wide dynamic range from +13 dBm to -136 dBm below 2500 MHz
- Fast frequency switching supports rapid test sequencing
- Clean spectral output with suppressed harmonics and subharmonics
Typical Applications
- High-volume receiver manufacturing and characterization
- Semi-automated test systems requiring repeatable signal generation
- Filter and amplifier validation across UHF and microwave bands
- Production test environments demanding consistent phase noise and spectral purity
Compatibility & Integration The 8648D operates with 50-ohm RF systems. Output protection to 50 watts (≤2000 MHz) and 25 watts (≤4000 MHz) safeguards against reflected power. Option 1EA High Power extends maximum leveled output to +20 dBm at 1000 MHz for demanding test scenarios.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 4000 MHz | Power Range (dBm): '+13 dBm to -136 dBm (below 2500 MHz) |
Agilent / Keysight 8648D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 8648D. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 8648D faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Agilent / Keysight 8648D price
This Agilent / Keysight 8648D is listed at $1,794.4. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 8648D calibration cost
NIST-traceable calibration for the Agilent / Keysight 8648D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →