Agilent / Keysight 8684D Microwave Signal Generator
Agilent / Keysight RF Signal Sources. Frequency Range: 5.4 GHz to 18.0 GHz, Power Range (dBm): +10 dBm (x2 band, Option 001), Voltage / Current Range: ±5% to -10%, 100/120/220/240 VAC, 48-66 Hz.
- Model
- Agilent / Keysight 8684D
- Calibration
- Available on request
- Price
- $12,778
- Status
- In stock
- RFQ ref
- 8684D
This unit
The Keysight 8684D is a microwave signal generator delivering precise RF stimulus across the 5.4 GHz to 18.0 GHz band. Built for radar testing, component characterization, and wireless communications, it combines wideband coverage with advanced modulation
AM, FM, and pulse - plus internal and external pulse control for demanding test environments.
Technical Specifications
Frequency Performance- Frequency range: 5.4 GHz to 18.0 GHz
- Resolution: 10 MHz (3½ digit LED display)
- Calibration accuracy: ±1.25% (5.4–9.0 GHz and 12.5–18.0 GHz); ±0.75% (9.0–12.5 GHz)
- Frequency stability (20 min warm-up): <30 kHz/min
- Frequency stability (60 min warm-up): <100 kHz/hr
- Temperature stability (0–55°C): <30 MHz
- Line voltage stability (±5% to -10% transients): <20 ppm Output & Spectral Purity
- Maximum output power (Option 001): +10 dBm in x2 band
- Harmonics: <-25 dBc (below 18 GHz at specified max output)
- Fundamental feedthrough (12.5–18.0 GHz): <-25 dBc Pulse Modulation
- Internal pulse rate: 10 Hz to 1 MHz (5 ranges, continuously adjustable)
- Pulse width: 50 ns to 100 ms (7 ranges, continuously adjustable)
- Sync delay: <50 ns to 100 ms (7 ranges, continuously adjustable); 20% accuracy
- RF rise/fall time: 80 dB
- Minimum pulse width: 1 MHz
- Peak power flatness: ±0.5 dB from CW level
- External pulse input: 0–1 MHz rate, >100 ns width; ON >+1.0 V peak, OFF <+0.4 V peak FM Modulation
- Internal FM: 1 kHz sawtooth sweep with deviation to ±10 MHz (x2 band)
- External FM: DC-coupled to 10 MHz rate
- Phase lock input sensitivity: -5 MHz/V typical
Key Features
- TTL-compatible pulse I/O and sync outputs
- Dual-band operation with extended coverage to 18.0 GHz
- Phase lock input for synchronization
- Compact 5.7" × 18" × 18.6" form factor (16.5 kg)
Electrical & Environmental
- Power: 100/120/220/240 VAC (±5%, -10%); 48–66 Hz; <200 VA max
- Operating range: 0–55°C
Compatibility & Integration Legacy instrument compatible with external pulse sources (0–1 MHz) and phase lock references. TTL I/O enables integration with automated test systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 5.4 GHz to 18.0 GHz | Power Range (dBm): '+10 dBm (x2 band, Option 001) | Voltage / Current Range: ±5% to -10%, 100/120/220/240 VAC, 48-66 Hz |
Agilent / Keysight 8684D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 8684D. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 8684D faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Agilent / Keysight 8684D price
This Agilent / Keysight 8684D is listed at $12,778. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 8684D calibration cost
NIST-traceable calibration for the Agilent / Keysight 8684D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →