Fluke Scopemeter Model 97

Fluke Digital Oscilloscopes. Bandwidth: 50 MHz dual-channel (DC to >, Voltage: 300 mV to 300 V (±0.5% ±5 counts).

Model
Fluke 97
Calibration
Available on request
Price
$760
Status
In stock
RFQ ref
97
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 97 Scopemeter is a handheld dual-channel digital storage oscilloscope integrated with a 3 2/3-digit digital multimeter. Designed for field service technicians and engineers, it delivers portable waveform capture and electrical measurements for troubleshooting and maintenance of electronic equipment across industrial and laboratory environments.


Technical Specifications

Oscilloscope

  • Bandwidth: 50 MHz dual-channel (DC to >50 MHz, 40 ns

  • External trigger input available

  • Autoset, digital delay, and pre-trigger by cycles, events, time, or zoom

  • Waveform processing: Average, Min Max, Record, Variable Persistence (running average up to 256)

  • Waveform mathematics: Add, Subtract, Multiply, Invert, Filter, Integrate

  • Storage: 8 waveforms and 10 front-panel setups

  • Measurements: 15 available with 5 simultaneous display; cursor analysis included Digital Multimeter

  • Display: 3 2/3 digits (>3000 counts)

  • DC voltage: 300 mV to 300 V (±0.5% ±5 counts)

  • AC voltage (True RMS): 300 mV to 250 V, AC+DC to 600 V (1700 V peak-to-peak)

  • Resistance: 30 Ω to 30 MΩ (30 Ω range: 0.01 Ω resolution, ±2.5% ±25 counts)

  • Diode test: up to 2.8 V

  • Continuity beeper included

  • Special modes: Min Max Average Record with Time Stamp, Relative, dBm, dBV, dBW, Audio Watts, %Scale, Frequency, %Duty Cycle, Smoothing


Key Features



  • Signal generator output (sine and square wave)

  • Component tester output (voltage or current ramp)

  • Battery-operated: 4 hours typical on internal Ni-Cad or alkaline C-cell batteries

  • Backlight available


Typical Applications Field service diagnosis, equipment maintenance, circuit troubleshooting, waveform analysis, and electrical parameter verification.


Compatibility & Integration External trigger input accommodates third-party signal sources and synchronization requirements.

Specifications

ParameterValue
Frequency RangeDC to >50 MHz | Voltage / Current Range: DC 300 mV to 300 V

Fluke 97 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 97. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 97 price

This Fluke 97 is listed at $760. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 97 calibration cost

NIST-traceable calibration for the Fluke 97 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →