Burleigh WA-2500 VIS/NIR/IR Wavemeter

The Burleigh WA-2500 is a high-precision wavemeter designed for accurate wavelength measurement in the visible, near-infrared (NIR), and infrared (IR) spectral regions. It offers reliable performance for various applications requiring precise wavelength determination.

Model
Burleigh WA-2500
Calibration
Available on request
Price
$5,170
Status
In stock
RFQ ref
WA-2500
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Burleigh WA-2500 VIS/NIR/IR Wavemeter is a precision instrument for accurate wavelength measurement of continuous-wave laser sources across the visible, near-infrared, and infrared spectral regions. Built around a compact scanning Michelson interferometer and high-resolution Moiré gauge, it delivers ±1 part in 10,000 accuracy with interchangeable detectors for broad spectral coverage. The wavemeter measures tunable lasers including dye, Ti:Sapphire, and diode lasers with coherence lengths down to 150 GHz linewidth and extends to 3000 GHz with Auto-Resolution adjustment.


Technical Specifications



  • Wavelength Range: 400 nm to 1800 nm

  • Accuracy: ±1 part in 10,000 (0.1 nm or 1 cm⁻¹ at 1000 nm)

  • Display Resolution: 0.01 nm (0.1 cm⁻¹)

  • VIS Detector: 400 nm to 1100 nm

  • IR Detector: 600 nm to 1800 nm

  • Laser Linewidth Measurement: 150 GHz (5 cm⁻¹) at specified accuracy; Auto-Resolution up to 3000 GHz

  • Minimum Input Power: 20 µW

  • Maximum Incident Power: 100 mW on beam receiver (2.5 mm aperture); power density adjustment required for smaller beams

  • AC Power Input: 100/115/230 V AC


Key Features



  • Normal measurement mode updates every 0.2 seconds; Average mode accumulates 10 sequential measurements with 2-second display updates

  • Six-digit LED display with selectable units (nm or cm⁻¹) in vacuum or air

  • Bar-graph intensity meter for fringe signal monitoring and alignment

  • Signal condition indicators: "LO SIG" or "HI SIG" warnings

  • "COH Er" display flag indicates linewidth exceeding 3000 GHz

  • On-board calibration function

  • Beam receiver with 2.5 mm coupling head aperture and 3-meter patch cord cable


Typical Applications



  • Tunable laser wavelength verification and characterization

  • Dye laser output measurement

  • Ti:Sapphire laser wavelength determination

  • Diode laser spectral monitoring


Compatibility & Integration



  • RS-232 interface at 2400 Baud

  • Three BNC diagnostic outputs: MONITOR, WINDOW, and TRIGGER

  • Physical dimensions: 24 × 16 × 12 inches; Weight: 25 lbs

Specifications

ParameterValue
Voltage / Current Range100/115/230 V AC | Wavelength Range: 400 nm to 1800 nm

Burleigh WA-2500 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Burleigh WA-2500. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Burleigh WA-2500 faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.

Burleigh WA-2500 price

This Burleigh WA-2500 is listed at $5,170. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Burleigh WA-2500 calibration cost

NIST-traceable calibration for the Burleigh WA-2500 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents