Stanford Research DS360 – Ultra-Low Distortion Function Generator

Stanford Research Systems Function Generators. Frequency range: 1 mHz to 200 kHz, Resolution: 6-digit, Accuracy: 0.0025%.

Model
Stanford Research Systems DS360
Calibration
Available on request
Price
$4,095
Status
In stock
RFQ ref
DS360
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research Systems DS360 is an ultra-low distortion function generator engineered for precision signal generation in demanding measurement and audio applications. It combines Direct Digital Synthesis with analog-grade performance to deliver THD below 0.001%, frequency accuracy of 0.0025%, and exceptional waveform purity across a 1 mHz to 200 kHz range.


Technical Specifications

Frequency Performance

  • Frequency range: 1 mHz to 200 kHz

  • Frequency resolution: 6-digit

  • Frequency accuracy: 0.0025%

  • Frequency stability: 25 ppm Distortion & Signal Quality

  • THD at 1 Vrms unbalanced / 2 Vrms balanced:


Below 5 kHz: −110 dB typical, −106 dB maximum - 5 to 20 kHz: −104 dB typical, −100 dB maximum - 20 to 40 kHz: −100 dB typical, −96 dB maximum - 40 to 100 kHz: −90 dB typical, −85 dB maximum - 100 to 200 kHz: −76 dB typical, −68 dB maximum

THD at 10 Vrms unbalanced / 20 Vrms balanced:


Below 5 kHz: −109 dB typical, −105 dB maximum - 5 to 20 kHz: −103 dB typical, −99 dB maximum - 20 to 40 kHz: −98 dB typical, −93 dB maximum - 40 to 100 kHz: −88 dB typical Amplitude Specifications

Output range: 20 µVpp to 40 Vpp

Unbalanced output: 0 to ±7.4 VDC (50 Ω load), 0 to ±10.0 VDC (600 Ω load), 0 to ±20.0 VDC (Hi-Z load)


Key Features



  • 20-bit D/A converter with DSP and DDS architecture

  • Waveforms: Sine, square, two-tone (independent frequency/amplitude control), white noise, pink noise, band-limited white noise

  • Two-tone formats: SMPTE, DIM, CCIF for intermodulation distortion testing

  • Frequency sweep and tone burst capabilities

  • Low output noise with optimized shielding and board layout

  • Requires 1 hour warm-up for performance verification


Typical Applications



  • Audio system characterization and distortion analysis

  • Precision impedance and network measurements

  • Sensitive electronics testing

  • Intermodulation distortion (IMD) evaluation

  • Frequency sweep and parametric testing


Compatibility & Integration



  • RS-232 interface for device control and automation

  • GPIB interface for instrumentation system integration

  • User-accessible front panel controls

Specifications

ParameterValue
Frequency Range1 mHz to 200 kHz | Voltage / Current Range: 0 to ±10.0 VDC (600 Ω), 0 to ±20.0 VDC (Hi-Z), 20 µVpp to 40 Vpp

Stanford Research Systems DS360 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems DS360. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Stanford Research Systems DS360 faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

Stanford Research Systems DS360 price

This Stanford Research Systems DS360 is listed at $4,095. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research Systems DS360 calibration cost

NIST-traceable calibration for the Stanford Research Systems DS360 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents