Interface Technology DT9110 Daughter Card
Interface Technology VXI Modules. Voltage: ** 4.75 V to 5.25 V (nominal 5.0 V), Current: ** 300 mA @ 5 V, Voltage: ** GND - 0.5 V to 6.0 V.
- Model
- Interface Technology DT9110
- Calibration
- Available on request
- Price
- $350
- Status
- In stock
- RFQ ref
- DT9110
This unit
The Interface Technology DT9110 is a daughter card that adds register-based VXI interface capability to VXIbus data acquisition systems. Built around the IT9010 VXIntegrator chip, it integrates essential VXI interface elements into a compact 13.5 square inch form factor compatible with B-size, C-size, and D-size VXI modules. The card implements all VXI specification configuration registers - including Device Dependent and A24/A32 VMEbus registers - and provides high current buffers for direct VME/VXI backplane signal driving plus integrated interrupt generation circuitry. Supply current is 300 mA @ 5 V. The DT9110 operates from 0 °C to +50 °C and is suitable for OEM integration, custom development, and laboratory or industrial applications requiring VXI protocol support.
Technical Specifications
Core Technology: IT9010 VXIntegrator chip
Interface Type: Register-based VXI interface
Board Area: 13.5 square inches
Board Thickness: 0.062 inches
Component Height: Up to 0.30 inches
Module Compatibility: B-size, C-size, and D-size VXI modules
Hole Spacing: 0.100 inches
Hole Diameter: 0.042 ± 0.003 inches
Electrical Characteristics
Supply Voltage: 4.75 V to 5.25 V (nominal 5.0 V)
Input Logic Levels: Vih 2.2 V (min), Vil 0.8 V (max)
Supply Current: 300 mA @ 5 V
Output Current Ratings: Standard ±40 mA, Medium Drive ±40 to +80 mA, High Drive ±90 to +180 mA, Open-Collector -128 mA, Bidirectional I/O1 ±48 mA, Bidirectional I/O2 ±128 mA
Absolute Maximum Supply Voltage: GND - 0.5 V to 6.0 V
Operating Temperature: 0 °C to +50 °C
Storage Temperature: -40 °C to +70 °C
Key Features
High current buffers for direct VME/VXI backplane signal driving
Complete VXI specification register implementation
Interrupt generation circuitry
Compact footprint preserving significant design space on host module
Compatibility & Integration Designed for VXIbus-compliant systems and compatible with VXI prototyping modules such as the Interface Technology BB9210.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 300 mA @ 5 V, 4.75 V to 5.25 V |
Interface Technology DT9110 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Interface Technology DT9110. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Interface Technology DT9110 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Interface Technology DT9110 price
This Interface Technology DT9110 is listed at $350. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Interface Technology DT9110 calibration cost
NIST-traceable calibration for the Interface Technology DT9110 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →