Keysight / Agilent / HP E1433B 8-Channel 196 kSa/s Digitizer Plus DSP (Base Configuration)

Keysight / Agilent / HP VXI Modules. Channels: ** 8 independent inputs, Resolution: ** 16-bit.

Model
Keysight / Agilent / HP E1433B
Calibration
Available on request
Price
$3,200
Status
In stock
RFQ ref
E1433B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight E1433B is an 8-channel, 16-bit digitizer module with onboard DSP designed for VXIbus systems. It delivers 196 kSa/s per channel sampling rate and integrates transducer signal conditioning, anti-alias filtering, and real-time measurement computation into a single C-size VXI module. Each channel supports independent range, differential/single-ended, and AC/DC coupling configuration, eliminating the need for external signal conditioning in many applications.

Technical Specifications

Channels: 8 independent inputs

Resolution: 16-bit

Sampling Rate: 196,608 Sa/s per channel maximum

Memory: 4 MB RAM standard; up to 32 MB available

DSP: Onboard processor for real-time data processing and analysis

Form Factor: C-size, single-wide VXI module (1-slot)

Input Signal Conditioning: Integrated transducer conditioning and anti-alias protection

Channel Configuration: Independent settings per channel - range, coupling mode (AC/DC), and input type (differential/single-ended)

Key Features

Real-time high-speed measurement computation on-module

Compatible with external breakout boxes for voltage, IEPE, microphone, and piezoelectric charge transducers

Option 1D1 enables real-time octave analysis across all eight channels simultaneously (3.15 Hz to 20 kHz third-octave, 4 Hz to 16 kHz full-octave)

Optional tachometer input (Option AYF) and local bus interface (Option UGV)

Optional arbitrary source module (Option 1D4)

Typical Applications Data acquisition systems requiring simultaneous multi-channel sampling, transducer signal analysis, and onboard DSP computation. Applications include structural health monitoring, vibration analysis, acoustic measurement, and real-time waveform processing in VXI-based test environments.

Compatibility & Integration Designed for VXIbus systems. Requires external breakout boxes for transducer interfacing. Simplifies system integration by consolidating signal conditioning, filtering, digitization, and computation into a single module.

Specifications

ParameterValue
Frequency Range3.15 Hz to 20 kHz (third-octave, Option 1D1), Option 1D1)

Keysight / Agilent / HP E1433B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent / HP E1433B. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keysight / Agilent / HP E1433B faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Keysight / Agilent / HP E1433B price

This Keysight / Agilent / HP E1433B is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight / Agilent / HP E1433B calibration cost

NIST-traceable calibration for the Keysight / Agilent / HP E1433B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →