Agilent/Keysight E1752A
Agilent / Keysight VXI Modules. Frequency range: 100 kHz to 10 MHz (or 1 pps to 10 million pps), Channels: Six buffered outputs.
- Model
- Agilent / Keysight E1752A
- Calibration
- Available on request
- Price
- $1,050
- Status
- In stock
- RFQ ref
- E1752A
This unit
The Agilent/Keysight E1752A is a C-size VXI pulse distribution amplifier that buffers and distributes clock signals, timing pulses, and broadband waveforms across up to six isolated outputs. Operating from 100 kHz to 10 MHz (or 1 pps to 10 million pulses per second), the module accepts input levels between +7 dBm and +19 dBm and maintains phase and frequency integrity across varying environmental conditions. High port-to-port isolation and low crosstalk make it suitable for precision timing distribution in laboratory, factory, and automated test equipment systems.
Technical Specifications
- Input frequency range: 100 kHz to 10 MHz (or 1 pps to 10 million pps)
- Input level: +7 dBm to +19 dBm (logic: LO ≤ 0.8 V, HI ≥ 2.0 V)
- Maximum damage level: +27 dBm (+14 V, −9 V)
- Input impedance: 50 Ω
- Harmonic distortion: <−45 dBc
- Spurious modulation: <−100 dBc
- Output channels: Six buffered outputs
- Form factor: C-size, 1-slot, register-based VXI module
- Phase noise: Dependent on input level; specifications available
Key Features
- Built-in automatic gain control (AGC) for phase stability and rapid deployment without manual level adjustment
- High isolation between output ports to minimize crosstalk in multi-channel distribution
- Channel fault alarm with front-panel status indicators for system monitoring
- VXIbus register access enables real-time signal presence/absence detection on individual channels
- Preserves input signal phase and frequency characteristics under temperature and humidity variations
Typical Applications
- Precision clock distribution in ATE and test systems
- 1 pps timing reference distribution
- Broadband pulse and sine wave buffering
- Multi-channel signal distribution in synchronized measurement environments
Compatibility & Integration Designed as a plug-in module for VXIbus systems, the E1752A integrates via register-based VXI controller communication. Accepts standard clock signals, timing pulses, sine waves, and pulse trains across its 50 Ω input.
Agilent / Keysight E1752A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E1752A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight E1752A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Agilent / Keysight E1752A price
This Agilent / Keysight E1752A is listed at $1,050. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight E1752A calibration cost
NIST-traceable calibration for the Agilent / Keysight E1752A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →