Fujikura FSM-11S SpliceMate Fusion Splicer

Fujikura Fusion Splicers. Model: FSM-11S.

Model
Fujikura FSM-11S
Calibration
Available on request
Price
$1,650
Status
In stock
RFQ ref
FSM-11S
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fujikura FSM-11S is a compact and user-friendly fusion splicer designed for basic fiber splicing needs. It is lightweight and easy to transport, making it ideal for field use. The FSM-11S features automated splicing functions, simplifying the splicing process for technicians. It supports both single-mode and multimode fibers and delivers consistent, low-loss splices. The splicer includes a built-in heater for splice protection sleeves, ensuring secure and reliable fiber connections.

Specifications

ParameterValue
Voltage / Current Range10-15 V DC, 100-240 V AC

Fujikura FSM-11S — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fujikura FSM-11S. Calibration covers arc calibration (arc power and duration), V-groove alignment verification, cleave angle detection accuracy, splice loss estimation accuracy, and heating oven temperature calibration. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fujikura FSM-11S faults: electrode wear, V-groove contamination or chipping, motor alignment drift, high arc voltage errors. Common repairs include electrode replacement (typically every 2,000-3,000 arcs), V-groove cleaning or replacement, motor and actuator alignment, and camera/CCD replacement. Fujikura FSM and Sumitomo Type series parts are stocked.

Fujikura FSM-11S price

This Fujikura FSM-11S is listed at $1,650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fujikura FSM-11S calibration cost

NIST-traceable calibration for the Fujikura FSM-11S is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers arc calibration (arc power and duration), V-groove alignment verification, cleave angle detection accuracy, splice loss estimation accuracy, and heating oven temperature calibration. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents