JDS Uniphase HA9 - HA9543-FAS2
JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ±0.1 dB.
- Model
- JDS Uniphase HA9-HA9543-FAS2
- Calibration
- Available on request
- Price
- $1,850
- Status
- In stock
- RFQ ref
- HA9-HA9543-FAS2
This unit
The JDS Uniphase HA9-HA9543-FAS2 is a programmable optical attenuator that delivers precise attenuation control across extended wavelength ranges for demanding laboratory and field test environments. This instrument provides attenuation up to 100 dB with 0.01 dB resolution and ±0.1 dB accuracy, making it essential for power meter calibration, bit error rate testing, and fiber optic loss simulation.
Technical Specifications
Attenuation Range: Up to 100 dB
Resolution: 0.01 dB nominal
Accuracy: ±0.1 dB
Repeatability: 0.01 dB
Wavelength Range: 1200–1700 nm standard; optional 750–1700 nm configuration available
Wavelength Dependence: ±0.05 dB maximum over 1530–1625 nm
Polarization Dependent Loss (PDL): Typically 0.03 dB
Return Loss: ≤60 dB
Maximum Input Power: 200 mW
Built-in Beam Block: Yes
Key Features
Half-rack form factor for space-constrained installations
SCPI/HP8156A-compatible command set with keyboard front-panel control
Dual remote control via GPIB (IEEE 488.1) and RS232
Optional built-in couplers (2/98, 10/90, 30/70, 50/50) for tap or dual input/output access
LabVIEW driver support for automated test sequences
Operating temperature range: 0–40 °C
Storage temperature range: –40 to 60 °C
Typical Applications
Power meter testing and linearity calibration
Bit error rate (BER) testing in high-speed digital systems
Optical link loss simulation and characterization
EDFA output power assessment
Analog transmission and multi-channel AM system evaluation
High bit-rate PCM system testing
Compatibility & Integration
Fiber Types: Single-mode (SMF) at full attenuation range; multimode (MMF) with 45 dB maximum attenuation
Supports 9/125 µm SMF specification
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 1200–1700 nm (standard) |
JDS Uniphase HA9-HA9543-FAS2 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9-HA9543-FAS2. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase HA9-HA9543-FAS2 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase HA9-HA9543-FAS2 price
This JDS Uniphase HA9-HA9543-FAS2 is listed at $1,850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase HA9-HA9543-FAS2 calibration cost
NIST-traceable calibration for the JDS Uniphase HA9-HA9543-FAS2 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →