JDS Uniphase HA9 - HA9543-FAS2

JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ±0.1 dB.

Model
JDS Uniphase HA9-HA9543-FAS2
Calibration
Available on request
Price
$1,850
Status
In stock
RFQ ref
HA9-HA9543-FAS2
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase HA9-HA9543-FAS2 is a programmable optical attenuator that delivers precise attenuation control across extended wavelength ranges for demanding laboratory and field test environments. This instrument provides attenuation up to 100 dB with 0.01 dB resolution and ±0.1 dB accuracy, making it essential for power meter calibration, bit error rate testing, and fiber optic loss simulation.

Technical Specifications

Attenuation Range: Up to 100 dB

Resolution: 0.01 dB nominal

Accuracy: ±0.1 dB

Repeatability: 0.01 dB

Wavelength Range: 1200–1700 nm standard; optional 750–1700 nm configuration available

Wavelength Dependence: ±0.05 dB maximum over 1530–1625 nm

Polarization Dependent Loss (PDL): Typically 0.03 dB

Return Loss: ≤60 dB

Maximum Input Power: 200 mW

Built-in Beam Block: Yes

Key Features

Half-rack form factor for space-constrained installations

SCPI/HP8156A-compatible command set with keyboard front-panel control

Dual remote control via GPIB (IEEE 488.1) and RS232

Optional built-in couplers (2/98, 10/90, 30/70, 50/50) for tap or dual input/output access

LabVIEW driver support for automated test sequences

Operating temperature range: 0–40 °C

Storage temperature range: –40 to 60 °C

Typical Applications

Power meter testing and linearity calibration

Bit error rate (BER) testing in high-speed digital systems

Optical link loss simulation and characterization

EDFA output power assessment

Analog transmission and multi-channel AM system evaluation

High bit-rate PCM system testing

Compatibility & Integration

Fiber Types: Single-mode (SMF) at full attenuation range; multimode (MMF) with 45 dB maximum attenuation

Supports 9/125 µm SMF specification

Specifications

ParameterValue
Wavelength Range1200–1700 nm (standard)

JDS Uniphase HA9-HA9543-FAS2 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9-HA9543-FAS2. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase HA9-HA9543-FAS2 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase HA9-HA9543-FAS2 price

This JDS Uniphase HA9-HA9543-FAS2 is listed at $1,850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase HA9-HA9543-FAS2 calibration cost

NIST-traceable calibration for the JDS Uniphase HA9-HA9543-FAS2 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →