JDS Uniphase JDSU HA9 HA97E+18KFA1 Programmable Attenuator
JDS Uniphase/JDSU Optical Attenuators. Resolution: 0.01 dB, Accuracy: ±0.03 dB typical, Voltage: 100–240 V AC.
- Model
- JDS Uniphase/JDSU HA9/HA97E+18KFA1
- Calibration
- Available on request
- Price
- $2,930
- Status
- In stock
- RFQ ref
- HA9/HA97E+18KFA1
This unit
The JDS Uniphase JDSU HA9 HA97E+18KFA1 is a programmable optical attenuator delivering precise control of optical signal power across extended attenuation ranges. Operating from 1200 to 1700 nm (optional 750–1700 nm), this instrument provides 0 to 100 dB attenuation with 0.01 dB resolution and ±0.03 dB typical accuracy. Designed for test labs, system characterization, and demanding measurement environments, it combines high repeatability with low insertion loss and exceptional return loss performance.
Technical Specifications
- Attenuation Range: 0 to 100 dB
- Attenuation Resolution: 0.01 dB
- Attenuation Accuracy: ±0.03 dB typical; ±0.1 dB maximum
- Repeatability: 0.01 dB
- Wavelength Range: 1200–1700 nm standard; 750–1700 nm optional (60 dB max for HA9W)
- Insertion Loss (Single-mode): 1.2 dB typical, 1.5 dB maximum; with connectors 2.5 dB
- Return Loss (Single-mode): >45 dB; >60 dB analog
- Polarization Dependent Loss: 0.03 dB typical, 0.08 dB maximum
- Wavelength Dependence: ±0.05 dB max over 1530–1625 nm
- Maximum Optical Input Power: 200 mW
- Beam Block Attenuation: >110 dB
- Beam Block Speed: <20 ms
- Attenuation Change Rate (0–100 dB): ≤2.5 seconds
- Input Voltage: 100–240 V AC, 50–60 Hz
- Power Consumption: 80 VA maximum
- Dimensions: 21.2 × 8.9 × 35.5 cm (W×H×D)
- Rack Mounting: 19 inch, 2U high, 1/2 rack width
- Weight: 4 kg
- Operating Temperature: 0 to 40 °C
- Storage Temperature: -40 to 60 °C
Key Features
- SCPI/HP8156A compatible command set
- GPIB (IEEE 488.2) and RS232 control interfaces
- Front panel keyboard operation
- SC/PC and SC/APC connector options
- Optional built-in couplers (2/98, 10/90, 30/70, 50/50) and 1×2 switch
- Single-mode 9/125 µm fiber with front bulkhead or back panel pigtail ports
- 5 V driver key for external or internal switch control
Typical Applications
- Power meter testing and calibration
- Power meter linearity verification
- Analog transmission characterization
- Bit error rate measurements
- General optical test and laboratory work
Compatibility & Integration Standard SC/PC connectors support rapid deployment in existing test benches. Optional couplers and switches extend functionality for multi-port and tap configurations. Dual control via front panel and remote interfaces (GPIB, RS232) enables both manual and automated measurement sequences.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 100–240 V AC, 50–60 Hz |
| 80 VA maximum | Wavelength Range | 1200–1700 nm (standard) |
JDS Uniphase/JDSU HA9/HA97E+18KFA1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase/JDSU HA9/HA97E+18KFA1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase/JDSU HA9/HA97E+18KFA1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase/JDSU HA9/HA97E+18KFA1 price
This JDS Uniphase/JDSU HA9/HA97E+18KFA1 is listed at $2,930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase/JDSU HA9/HA97E+18KFA1 calibration cost
NIST-traceable calibration for the JDS Uniphase/JDSU HA9/HA97E+18KFA1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →