JDS Uniphase HA97E+10KSU1
JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ±0.03 dB typical.
- Model
- JDS Uniphase HA97E+10KSU1
- Calibration
- Available on request
- Price
- $2,100
- Status
- In stock
- RFQ ref
- HA97E+10KSU1
This unit
The JDS Uniphase HA97E+10KSU1 is a programmable optical attenuator for precise control of optical power across telecommunications and laboratory environments. It delivers attenuation up to 100 dB with 0.01 dB resolution and ±0.03 dB typical accuracy, making it suitable for power meter calibration, BER testing, and EDFA characterization. The unit accepts front-panel keypad control, GPIB, and RS232 commands via SCPI/HP8156A-compatible protocol. SC/APC connectors provide optical interfacing, with optional internal couplers (10/90, 50/50, 2/98, 30/70) and 1:2 switch capability for multi-port applications.
Technical Specifications
Wavelength Range: 1200 nm to 1700 nm (standard); 750 nm to 1700 nm (wide range with 60 dB maximum attenuation)
Attenuation Range: Up to 100 dB (60 dB for wide wavelength option)
Attenuation Resolution: 0.01 dB nominal
Attenuation Accuracy: ±0.03 dB typical; ±0.1 dB maximum at constant temperature, wavelength, and polarization after 30-minute warm-up
Repeatability: ±0.005 dB typical; ±0.01 dB maximum
Insertion Loss: Typically 2.5 dB (including connectors)
Return Loss: >60 dB (analog)
Polarization Dependent Loss (PDL): 0.03 dB typical; 0.08 dB maximum
Maximum Input Power: 200 mW
Change Rate: ≤2.5 seconds (0 to 100 dB)
Beam Block Attenuation: >110 dB
Beam Block Speed: <20 ms
Discrete Internal Optical Reflections: Better than 60 dB
Key Features
Single-mode 9/125 µm fiber compatibility
Minimized cavity effects and spectral ripple
Low wavelength dependence (<±0.05 dB over 1530–1625 nm)
Front-panel SC/APC bulkhead connectors
5 V driver key for external or internal switch control
Typical Applications
Optical power meter linearity calibration
Bit error rate (BER) testing
Analog transmission characterization
EDFA output power analysis
Fiber optic link loss simulation
Multichannel AM system evaluation
Compatibility & Integration Optional couplers and switches integrate directly into the attenuator, providing output taps or access to dual inputs/outputs without external hardware. SCPI command compatibility simplifies integration into existing automated test environments.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 5 V (driver key) | Wavelength Range: 1200 nm to 1700 nm (standard) |
JDS Uniphase HA97E+10KSU1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA97E+10KSU1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase HA97E+10KSU1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase HA97E+10KSU1 price
This JDS Uniphase HA97E+10KSU1 is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase HA97E+10KSU1 calibration cost
NIST-traceable calibration for the JDS Uniphase HA97E+10KSU1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →