JDS Uniphase HA97E+10KSU1

JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB nominal, Accuracy: ** ±0.03 dB typical.

Model
JDS Uniphase HA97E+10KSU1
Calibration
Available on request
Price
$2,100
Status
In stock
RFQ ref
HA97E+10KSU1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase HA97E+10KSU1 is a programmable optical attenuator for precise control of optical power across telecommunications and laboratory environments. It delivers attenuation up to 100 dB with 0.01 dB resolution and ±0.03 dB typical accuracy, making it suitable for power meter calibration, BER testing, and EDFA characterization. The unit accepts front-panel keypad control, GPIB, and RS232 commands via SCPI/HP8156A-compatible protocol. SC/APC connectors provide optical interfacing, with optional internal couplers (10/90, 50/50, 2/98, 30/70) and 1:2 switch capability for multi-port applications.

Technical Specifications

Wavelength Range: 1200 nm to 1700 nm (standard); 750 nm to 1700 nm (wide range with 60 dB maximum attenuation)

Attenuation Range: Up to 100 dB (60 dB for wide wavelength option)

Attenuation Resolution: 0.01 dB nominal

Attenuation Accuracy: ±0.03 dB typical; ±0.1 dB maximum at constant temperature, wavelength, and polarization after 30-minute warm-up

Repeatability: ±0.005 dB typical; ±0.01 dB maximum

Insertion Loss: Typically 2.5 dB (including connectors)

Return Loss: >60 dB (analog)

Polarization Dependent Loss (PDL): 0.03 dB typical; 0.08 dB maximum

Maximum Input Power: 200 mW

Change Rate: ≤2.5 seconds (0 to 100 dB)

Beam Block Attenuation: >110 dB

Beam Block Speed: <20 ms

Discrete Internal Optical Reflections: Better than 60 dB

Key Features

Single-mode 9/125 µm fiber compatibility

Minimized cavity effects and spectral ripple

Low wavelength dependence (<±0.05 dB over 1530–1625 nm)

Front-panel SC/APC bulkhead connectors

5 V driver key for external or internal switch control

Typical Applications

Optical power meter linearity calibration

Bit error rate (BER) testing

Analog transmission characterization

EDFA output power analysis

Fiber optic link loss simulation

Multichannel AM system evaluation

Compatibility & Integration Optional couplers and switches integrate directly into the attenuator, providing output taps or access to dual inputs/outputs without external hardware. SCPI command compatibility simplifies integration into existing automated test environments.

Specifications

ParameterValue
Voltage / Current Range5 V (driver key) | Wavelength Range: 1200 nm to 1700 nm (standard)

JDS Uniphase HA97E+10KSU1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA97E+10KSU1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase HA97E+10KSU1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase HA97E+10KSU1 price

This JDS Uniphase HA97E+10KSU1 is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase HA97E+10KSU1 calibration cost

NIST-traceable calibration for the JDS Uniphase HA97E+10KSU1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents