This unit

The JDSU HA9W2 optical attenuator is a precision instrument specifically designed for multimode fiber optic systems. Operating in the 700-1750nm wavelength range, it is suitable for 62.5/125um fiber. This calibrated attenuator allows for accurate control of optical signal strength, crucial for performance evaluation, system optimization, and component testing in fiber optic networks.

JDSU HA9W2 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDSU HA9W2. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDSU HA9W2 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDSU HA9W2 price

This JDSU HA9W2 is listed at $4,930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDSU HA9W2 calibration cost

NIST-traceable calibration for the JDSU HA9W2 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →