Anritsu MA2424A Power Sensor, Thermocouple, 10 MHz-40GHz
Anritsu MA2424A Power Sensor, Thermocouple, operates over 10 MHz to 40 GHz and provides stable thermal power detection. Its solid design and wide frequency range make it a reliable choice for thermal power measurements in complex RF systems.
- Model
- Anritsu MA2424A
- Calibration
- Available on request
- Price · starting from
- $3,480
- Status
- In stock
- RFQ ref
- MA2424A
This unit
The Anritsu MA2424A is a thermocouple-based power sensor for average power measurement across 10 MHz to 40 GHz. It detects thermal gradients using Seebeck elements to deliver true power readings independent of waveform shape. An internal EEPROM stores calibration factors and linearity correction data, which Anritsu power meters read automatically for calibrated output.
Technical Specifications
- Frequency Range: 10 MHz to 40 GHz
- Dynamic Range: –30 dBm to +20 dBm
- Sensor Linearity: <1.3% to 18 GHz; 1.5% to 40 GHz
- Rise Time: <4.0 ms
- Temperature Accuracy (5°C to 50°C): <1.0%
- Maximum Input Power:
Continuous: +24 dBm - 1 µs peak: +30 dBm
DC: 2.2 V
Return Loss (SWR): - 10–50 MHz: <1.90 - 50–150 MHz: <1.17 - 0.15–2 GHz: <1.10 - 2–12.4 GHz: <1.15 - 18–32 GHz: <1.25 - 32–40 GHz: <1.30
RF Connector: K (male)
Key Features
- Seebeck element technology for waveform-independent average power detection
- Stored calibration and linearity correction via internal EEPROM
- Low return loss across full frequency range
- Excellent linearity performance across microwave and millimeter-wave bands
- Fast thermal response for dynamic power monitoring
Typical Applications
- RF power measurement in communication systems
- Microwave and millimeter-wave power monitoring
- Amplifier characterization and validation
- Transmitter power control and compliance testing
Compatibility & Integration Designed for direct integration with Anritsu ML2400, ML2430, ML2480, and ML2490 series power meters. Specific firmware revisions may be required for optimal compatibility across certain meter models.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 40 GHz | Power Range (dBm): '-30 dBm to +20 dBm | Voltage / Current Range: 2.2 V DC max |
Anritsu MA2424A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2424A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MA2424A price
This Anritsu MA2424A is listed at $3,480. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MA2424A calibration cost
NIST-traceable calibration for the Anritsu MA2424A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →