JDS Uniphase MAP200-MVOA-A2DSM

The JDS Uniphase MAP200-MVOA-A2DSM is a modular optical variable attenuator designed for precise control of optical signal power. It features a compact design and is suitable for integration into automated test systems and optical networks.

Model
JDS Uniphase MAP200-MVOA-A2DSM
Calibration
Available on request
Price
$2,100
Status
In stock
RFQ ref
MAP200-MVOA-A2DSM
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase MAP200-MVOA-A2DSM is a dual variable optical attenuator module for the MAP-200 platform, delivering precise optical power control across the telecom spectrum. This hot-swappable cassette combines stepper motor and filter-based attenuation with an integrated power monitor, enabling accurate signal management in automated test systems and optical networks. Ultra-low insertion loss (typically <1.0 dB), flat spectral response, and transition speeds up to 25 dB/s minimize measurement uncertainty and reduce test cycles.

Technical Specifications

Module Configuration: Dual attenuator with integrated power monitor

Insertion Loss: Typically 55 dB typical (PC/APC), >30 dB typical (PC)

Backreflection: Low, to minimize instabilities from reflected light

Shutter Isolation: 100 dB typical

Warm-up Time: 30 minutes

Operating Temperature: 0 to 50°C

Storage Temperature: -30 to 60°C

Operating Humidity: <90% RH non-condensing at 23°C; <20% at 50°C

Calibration Interval: 2 years

Dimensions: 4.06 × 13.26 × 37.03 cm

Weight: 1.3 kg

Key Features

High-accuracy, high-repeatability attenuation control

Spectral uniformity across the 1250–1650 nm band

Fast transition speed reduces test time overhead

Low backreflection design for stable operation

LXI Class C compliance with Ethernet connectivity

IVI driver support for multi-platform integration

Typical Applications

Optical signal power characterization

Automated attenuation testing in telecom and datacom

Power-dependent measurement validation

Dynamic range assessment

Compatibility & Integration The MVOA-A2DSM integrates into the MAP-200 modular platform as a hot-swappable cassette. Platform-level Ethernet connectivity and virtual instrument drivers enable rapid integration into diverse test frameworks without custom hardware interface design.

Specifications

ParameterValue
Wavelength Range1250 nm to 1650 nm

JDS Uniphase MAP200-MVOA-A2DSM — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase MAP200-MVOA-A2DSM. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase MAP200-MVOA-A2DSM faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase MAP200-MVOA-A2DSM price

This JDS Uniphase MAP200-MVOA-A2DSM is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase MAP200-MVOA-A2DSM calibration cost

NIST-traceable calibration for the JDS Uniphase MAP200-MVOA-A2DSM is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →