The Anritsu MS9001A1 is a optical spectrum analyzer delivering precise wavelength component analysis across the 0.6 to 1.75 µm range. Engineered for optical communication systems, this instrument provides accurate spectral characterization with dynamic range exceeding 40 dB and polarization-independent level measurement accuracy.


Technical Specifications



  • Wavelength Range: 0.6 to 1.75 µm (600 to 1750 nm)

  • Level Measurement Range: -70 dBm to +10 dBm

  • Level Measurement Accuracy: ±2 dB across specified wavelength range

  • Dynamic Range (Stray Light Level): Greater than 40 dB at ±1 nm from peak

  • Sweep Time: 0.3 seconds

  • Power Requirements: 100/115/120/200/220 Vac +10%


Key Features



  • Polarization-independent measurements ensure consistent accuracy regardless of signal polarization state

  • GPIB interface with 1000 data point memory capacity for automated test sequences and remote operation

  • Fast 0.3 second sweep time minimizes analysis duration for spectrum instability characterization

  • High dynamic range performance eliminates stray light artifacts within the critical ±1 nm measurement window


Typical Applications



  • Wavelength component analysis in optical communication systems

  • Spectral characterization of optical signals in networking infrastructure

  • Detailed spectral measurements for optical system validation and troubleshooting


Compatibility & Integration GPIB connectivity enables integration into automated test environments and supports remote instrument control. Data memory accommodates 1000 spectral points per measurement, facilitating comprehensive signal analysis and post-acquisition processing.

Specifications

ParameterValue
Power Range (dBm)'-70 dBm to +10 dBm | Voltage / Current Range: 100/115/120/200/220 Vac +10% | Wavelength Range: 0.6 to 1.75 µm (600 to 1750 nm)

Frequently Asked Questions

What does the Anritsu MS9001A1 measure and what is its wavelength range?
The MS9001A1 is an optical spectrum analyzer designed to measure optical power across a broad wavelength range of 0.6 to 1.75 µm (600 to 1750 nm), covering visible through near-infrared regions. It delivers power measurements from −70 dBm to +10 dBm with ±2 dB accuracy across the specified wavelength range, making it suitable for telecommunications, fiber optics testing, and photonics applications where precise spectral characterization is required.
What is the condition of this used MS9001A1, and what has been verified?
This Anritsu MS9001A1 is offered in used condition and has been inspected for functional operation before listing. We recommend independent calibration verification if measurement accuracy within ±2 dB is critical for your application, as calibration status from the previous owner may not be documented.
What does calibration cover for the Anritsu MS9001A1 and what is the cost?
Calibration service for the MS9001A1 is available separately starting at $450 and typically verifies power measurement accuracy across the full wavelength range and establishes traceability to NIST standards. We recommend confirming the specific calibration scope and turnaround time with our calibration team, as service duration depends on current workload and any repairs identified during inspection.
What interfaces and connectivity options does the MS9001A1 support?
The Anritsu MS9001A1 supports GPIB (IEEE 488) connectivity for remote control and data transfer to external systems and computers. AC power input is available in 100/115/120/200/220 Vac configurations with ±10% tolerance; please verify your facility voltage before operation and confirm any required adapters or power conditioning with our team.

Anritsu MS9001A1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9001A1. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9001A1 faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9001A1 price

This Anritsu MS9001A1 is listed at $2,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9001A1 calibration cost

NIST-traceable calibration for the Anritsu MS9001A1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →