Anritsu MS9710A – Optical Spectrum Analyzer
Anritsu Optical Spectrum Analyzers. Accuracy: ±0.3 nm (±0.05 nm with automatic calibration in, Resolution: 0.5 nm (typical for dynamic range measurements), Dynamic Range: 70 dB.
- Model
- Anritsu MS9710A
- Calibration
- Available on request
- Price
- $3,200
- Status
- In stock
- RFQ ref
- MS9710A
This unit
The Anritsu MS9710A is a optical spectrum analyzer designed for spectral characterization across the 600 nm to 1750 nm wavelength range. Built on diffraction-grating technology, it delivers 0.5 nm resolution, 70 dB dynamic range, and -90 dBm minimum sensitivity, enabling precise measurement of light sources, passive optical components, and WDM systems including DWDM channel analysis up to 300 channels.
Technical Specifications
- Wavelength Range: 600 nm to 1750 nm
- Wavelength Accuracy: ±0.3 nm (±0.05 nm with automatic calibration in 1.53–1.57 µm range)
- Resolution: 0.5 nm (typical for dynamic range measurements)
- Dynamic Range: 70 dB
- Measurement Range: -90 dBm to 20 dBm
- Minimum Sensitivity: -90 dBm RMS noise level (1.25–1.6 µm band)
- Polarization Dependency: ±0.05 dB at 1.55 µm band; ±0.1 dB at 1.3 µm band (0.5 nm resolution)
- Input Type: Fibered input
Key Features
- Automatic wavelength calibration for enhanced accuracy in the telecom C-band
- External trigger input for synchronized measurement of modulated and pulsed light
- Wavelength auto-calibration and tracking functionality
- Gate-time configuration for modulated/pulsed signal analysis
- OSNR measurement capability
Typical Applications
- Light source characterization (LEDs, Fabry-Perot LDs, DFB LDs)
- Loss wavelength characteristic measurement in optical devices and passive components (isolators, filters)
- WDM and DWDM system waveform analysis (up to 300 channels)
- Polarization Mode Dispersion (PMD) measurements
- EDFA noise figure and gain assessment
- Optical pulse, wavelength, power, and SNR measurements
Compatibility & Integration
- Monitor Output: VGA connector
- Data Transfer: IEEE 488 (GPIB) and RS-232C
- LabVIEW drivers available for both GPIB (MX971001G) and RS-232C (Z0283) interfaces
- Optional internal light sources: White Light Source (Option 02), Reference Wavelength Light Source (Option 05), SLD Light Source (Option 14), Wavelength Reference & SLD Light Source (Option 13)
- Optional Monitor Output (Option 06)
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '-90 dBm to 20 dBm | Wavelength Range: 600 nm to 1750 nm |
Frequently Asked Questions
- What does the Anritsu MS9710A measure and what is its wavelength range?
- The MS9710A is an optical spectrum analyzer designed to measure optical power across a wavelength range of 600 nm to 1750 nm, making it suitable for characterizing light sources, filters, and multiplexed optical signals in telecommunications and photonics applications. It delivers a dynamic range of 70 dB and a typical spectral resolution of 0.5 nm for dynamic range measurements, with power measurement capability from –90 dBm to +20 dBm. Wavelength accuracy is ±0.3 nm under standard conditions, improving to ±0.05 nm when automatic calibration is applied.
- What is the condition of this used MS9710A, and what was verified before listing?
- We list this unit as used, having verified optical and electrical functionality before inventory intake. All core measurements—wavelength accuracy, power measurement range, and spectral resolution—have been confirmed operational within specification. We do not perform full factory calibration prior to sale, but calibration services are available separately starting at $450 if traceable, standards-compliant documentation is required for your application.
- What does calibration cover for the MS9710A, and how much does it cost?
- Calibration for the MS9710A typically verifies wavelength accuracy and power measurement accuracy against NIST-traceable standards, restoring the ±0.05 nm automatic calibration capability. Calibration services start at $450 and are offered separately; turnaround time and specific scope depend on the calibration house and current workload. We can coordinate calibration through our preferred partners or support your choice of external calibration lab.
- What are the interface and connectivity options on the MS9710A?
- The MS9710A features GPIB (IEEE-488) connectivity for remote instrument control and data acquisition, enabling integration into automated test systems and lab environments. Compatible software drivers and communication protocols support standard SCPI command sets, allowing seamless integration with measurement automation platforms and data logging software. For detailed connectivity requirements or software compatibility questions specific to your test setup, we recommend consulting the instrument's user manual or contacting our technical team.
Anritsu MS9710A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9710A. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu MS9710A faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.
Anritsu MS9710A price
This Anritsu MS9710A is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MS9710A calibration cost
NIST-traceable calibration for the Anritsu MS9710A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →