Abaco Systems / GE QPCX-1553-G2-2MW High-Density PCI Interface Module

High-density PCI interface module for MIL-STD-1553 applications.

Model
Abaco Systems / GE QPCX-1553-G2-2MW
Calibration
Available on request
Price
$3,599
Status
In stock
RFQ ref
QPCX-1553-G2-2MW
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Abaco Systems / GE QPCX-1553-G2-2MW is a high-density PCI interface module for MIL-STD-1553 bus applications. This card delivers simultaneous multi-function operation as a Bus Controller, up to 31 Remote Terminals, and Bus Monitor. The two dual-redundant channels support comprehensive bus analysis, simulation, and data logging in both commercial and ruggedized deployments.


Technical Specifications

Hardware Architecture

  • Interface: PCI

  • Form Factor: PCI Card (6" × 3 7/8")

  • PCI Signaling: Universal (5 V or 3.3 V)

  • PCI Bus Speed: 66 MHz

  • Channels: Two dual-redundant channels

  • RAM per Channel: 1 Mbyte

  • Message Time-tagging: 64-bit, 25 nanosecond resolution Signal Conditioning

  • Coupling: Transformer or direct coupling (software selectable)

  • IRIG-B: Signal Receiver/Generator with GPS synchronization

  • On-board Test Bus: Yes

  • UUT Transformer Connection: Yes

  • Avionics-level Discretes: Yes


Key Features Bus Controller (BC)



  • Programmable major and minor frame content and timing

  • Extensive link-list structures

  • Mode Codes, Broadcast, and single-shot messaging

  • Real-time conditional branching

  • Programmable time delays and aperiodic messaging methods Remote Terminal (RT)

  • Supports simultaneous operation of up to 31 RTs

  • Data wrapping and multiple RT buffers

  • Programmable response time

  • 1760 startup time with Busy bit set

  • RT Map Monitoring and hardwired RT address lines Bus Monitor (BM)

  • 100% monitoring of fully loaded buses

  • error detection across multiple monitoring methods

  • Error injection and detection capabilities

  • Automatic or manual RT Status Bit control

  • Mode Code response generation Interface & Synchronization

  • Programmable input and output triggers

  • IRIG-B synchronization for time-critical operations


Typical Applications Airborne and ground-based avionics platforms requiring real-time MIL-STD-1553 bus control, monitoring, and analysis. Ideal for test benches, system integration environments, and applications demanding simultaneous BC/RT/BM operation.


Compatibility & Integration Designed for PCI backplane integration in 5 V and 3.3 V environments. Abstract API software accelerates application development and reduces integration time. Available in commercial and ruggedized configurations.

Specifications

ParameterValue
Voltage / Current Range5 V or 3.3 V

Abaco Systems / GE QPCX-1553-G2-2MW — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Abaco Systems / GE QPCX-1553-G2-2MW. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Abaco Systems / GE QPCX-1553-G2-2MW faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Abaco Systems / GE QPCX-1553-G2-2MW price

This Abaco Systems / GE QPCX-1553-G2-2MW is listed at $3,599. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Abaco Systems / GE QPCX-1553-G2-2MW calibration cost

NIST-traceable calibration for the Abaco Systems / GE QPCX-1553-G2-2MW is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →