Advantest R6552 Digital multimeter
Advantest Laboratory Measurement Instruments. Frequency Range: 20 Hz to 300 kHz, Voltage / Current Range: DC Voltage: 30 mV to 1000 V; AC Voltage: 300 mV to 700 V; DC Current: 3000 µA to 3000 mA; AC Current: 3000 µA to 3000 mA.
- Model
- Advantest R6552
- Calibration
- Available on request
- Price
- $179
- Status
- In stock
- RFQ ref
- R6552
This unit
The Advantest R6552 is a 5.5-digit digital multimeter engineered for precision measurement across R&D, manufacturing, and service environments. It delivers DC and AC voltage and current measurements, resistance in 2-wire and 4-wire configurations, frequency analysis, and diode testing with True RMS accuracy. The 319,999-count fluorescent display and sampling speeds up to 1000 samples/sec in BURST mode enable rapid signal capture, while GPIB and RS232 interfaces support remote automation and data logging.
Specialized modes - including (AC+DC) measurement for distorted waveforms and LONG-IT averaging - extend measurement capability in challenging signal conditions.
Technical Specifications
Measurement Functions:- DC Voltage: 30 mV to 1000 V, 0.1 µV resolution, 100 MΩ input impedance (lower ranges), 10.0 MΩ (higher ranges)
- AC Voltage: 300 mV to 700 V, True RMS, 20 Hz to 300 kHz, (AC+DC) capability for distorted waveforms
- DC Current: 3000 µA to 3000 mA, 10 nA resolution
- AC Current: 3000 µA to 3000 mA, True RMS, 20 Hz to 300 kHz
- Resistance: 30 Ω to 300 MΩ (2-wire and 4-wire), 100 µΩ resolution, low-power mode available
- Frequency: DC to 300 kHz measurement
- Diode and continuity testing Display & Sampling:
- 5.5-digit fluorescent display, 319,999 counts maximum
- FAST mode: 100 samples/sec (1000 samples/sec BURST); MED: 20 samples/sec; SLOW: 5 samples/sec
- LONG-IT mode: integral time 100 ms to 60 s in 10 ms steps Accuracy (1-year stability):
- DC Voltage: ±0.01% of reading
- AC Voltage: ±0.06% of reading
- DC Current: ±0.05% of reading
Key Features
- True RMS AC measurement eliminates error from waveform distortion
- Low-power resistance mode reduces self-heating during testing
- Bargraph display provides visual feedback alongside numeric readout
- High input impedance (100 MΩ minimum) minimizes circuit loading on voltage measurements
Typical Applications
- Component characterization and quality verification
- In-circuit troubleshooting and signal validation
- Automated test system integration via GPIB or RS232
Compatibility & Integration GPIB interface complies with IEEE-488.2-1987 (SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT1, C0, E2). RS232 serial connection supports direct instrument control and remote data acquisition.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 20 Hz to 300 kHz | Voltage / Current Range: DC Voltage: 30 mV to 1000 V |
| AC Voltage | 300 mV to 700 V |
| DC Current | 3000 µA to 3000 mA |
| AC Current | 3000 µA to 3000 mA |
Advantest R6552 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest R6552. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Advantest R6552 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Advantest R6552 price
This Advantest R6552 is listed at $179. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest R6552 calibration cost
NIST-traceable calibration for the Advantest R6552 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →