Astronics / EADS / Talon Instruments SR103 TTL I / O Module

Astronics / EADS / Talon Instruments VXI Modules.

Model
Astronics / EADS / Talon Instruments SR103
Calibration
Available on request
Price
$850
Status
In stock
RFQ ref
SR103
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The SR103 is a TTL I/O module designed for integration into the Astronics/EADS/Talon Instruments SR192 Digital Test Module, a VXI-based platform for stimulus and response applications in industrial and enterprise-level testing environments. The module functions as a plug-in component within larger scalable digital test systems, enabling multi-channel I/O stimulus and capture operations with synchronized timing across multiple chassis units.

Technical Specifications

Module Type: TTL I/O Module for SR192 VXI Digital Test Module

Logic Standard: TTL (Transistor-Transistor Logic)

Timing Rate: Up to 50 MHz

Data Rate: Up to 25 MHz (50 MHz multiplexed)

Output Drive: 50 mA source/sink

Memory Architecture: 5-memory architecture (Stimulus, Tristate, Record, Expect, Mask); memory depth per channel typically 128K bits, expandable to 256K bits when multiplexed

Signal Type: Single-ended or double-ended (differential) logic configuration

TTL Logic Levels: Low state -0.2 V dc to +0.8 V dc; High state 2.0 V dc to 5.25 V dc

Power Distribution: Module receives power through VXI chassis backplane

Key Features

Plug-in module architecture for two-slot, "C" size VXI chassis mounting

TTL logic level compatibility with standard digital devices

Configurable signal types: single-ended or differential I/O channels

Dual memory depth options for flexible stimulus and capture scenarios

Multiple timing/data rate configurations for diverse test protocols

Typical Applications

Digital stimulus and response testing in automated test equipment (ATE) environments

Multi-channel TTL signal generation and acquisition

Industrial and enterprise digital device validation

Scalable test system expansion within VXI chassis infrastructure

Compatibility & Integration The SR103 integrates directly into the SR192 platform, which supports system expansion to 1152 I/O channels within a single 13-slot chassis through synchronized multi-unit configurations. The module operates within the established SR192 I/O module family, which accommodates various logic options including fixed-voltage TTL, ECL, RS485/422, and variable voltage levels.

Specifications

ParameterValue
Frequency Range25 MHz data rate (50 MHz multiplexed), 50 MHz timing | Voltage / Current Range: 2.0 V dc to 5.25 V dc (high)
50 mA source/sink, TTL-0.2 V dc to +0.8 V dc (low)

Astronics / EADS / Talon Instruments SR103 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Talon Instruments SR103. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Astronics / EADS / Talon Instruments SR103 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Astronics / EADS / Talon Instruments SR103 price

This Astronics / EADS / Talon Instruments SR103 is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Astronics / EADS / Talon Instruments SR103 calibration cost

NIST-traceable calibration for the Astronics / EADS / Talon Instruments SR103 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents