JDS Uniphase TB9 JDSU TB9226+1SU1 Tunable Grating Filter 1460-1575nm
The JDS Uniphase TB9226+1SU1 is a Tunable Grating Filter, operating in the 1460-1575nm wavelength range. It provides wavelength selection and signal conditioning in optical communication systems.
- Model
- JDS Uniphase/JDSU TB9226+1SU1
- Calibration
- Available on request
- Price
- $4,830
- Status
- In stock
- RFQ ref
- TB9226+1SU1
This unit
The JDSU TB9226+1SU1 is a tunable grating filter engineered for precision wavelength selection across the 1460–1575 nm band. It delivers optical filtering for laboratory and production testing of single-mode fiber components and subsystems in optical communication systems. The device leverages diffraction grating technology to achieve steep wavelength isolation roll-off, outperforming traditional Fabry-Perot and interference filter architectures.
Primary applications include suppression of amplified spontaneous emission (ASE) in Erbium-Doped Fiber Amplifiers (EDFAs), removal of spontaneous emission from distributed feedback and tunable lasers, and characterization of wavelength-selective components.
Technical Specifications
- Wavelength Range: 1460–1575 nm
- Resolution: 0.01 nm
- FWHM (-3 dB bandwidth): As low as 0.22 nm; models available from 0.22–1.4 nm
- Insertion Loss: <6.0 dB
- Polarization Dependent Loss (PDL): 45 dB
- Tuning Repeatability: 0.05 nm
- Single-mode fiber input/output
- Operating Temperature: 10–40 °C
- Storage Temperature: 0–50 °C
- Power Supply: 100–240 VAC, 50–60 Hz
- Power Consumption: 80 VA maximum
- Warm-up Time: 1 hour to specification; 2 hours recommended before operation
Key Features
- Dual configuration options: single-pass and double-pass grating designs for optimal rejection and narrow bandwidth
- High rejection capability across the C and L telecommunications bands
- Six standard models with bandwidth and performance variations for application-specific deployment
- Front-panel keypad control with GPIB, RS-232, IEEE 488, and parallel/serial remote interfaces
Typical Applications
- ASE filtering in EDFA systems
- Spontaneous emission suppression from DFB and tunable laser sources
- Tunable laser-based component testing
- WDM and DWDM subsystem characterization
Compatibility & Integration The TB9226+1SU1 interfaces via front-panel keypad, GPIB, RS-232, and IEEE 488 protocols, enabling integration into automated test environments and manual laboratory setups.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 100–240 VAC, 50–60 Hz, 80 VA max | Wavelength Range: 1460–1575 nm |
JDS Uniphase/JDSU TB9226+1SU1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase/JDSU TB9226+1SU1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase/JDSU TB9226+1SU1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase/JDSU TB9226+1SU1 price
This JDS Uniphase/JDSU TB9226+1SU1 is listed at $4,830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase/JDSU TB9226+1SU1 calibration cost
NIST-traceable calibration for the JDS Uniphase/JDSU TB9226+1SU1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →