Tektronix TTR506A USB Vector Network Analyzer, 100 kHz to 6 GHz

Tektronix Vector Network Analyzers. Frequency range: 100 kHz to 6 GHz, Resolution: 1 Hz, Accuracy: ± 7.0 ppm (1 year calibration interval.

Model
Tektronix TTR506A
Calibration
Available on request
Price
$5,570
RFQ ref
TTR506A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Tektronix TTR506A is a two-port, two-path vector network analyzer delivering S-parameter measurements, cable and antenna characterization, and RF component testing across 100 kHz to 6 GHz. This compact USB-connected instrument combines high dynamic range - 125 dB from 200 MHz to 3 GHz and 122 dB from 3 GHz to 6 GHz - with trace noise below 0.008 dB RMS, enabling precise measurements in educational, research, and manufacturing settings.


Technical Specifications

Frequency & Reference

  • Frequency range: 100 kHz to 6 GHz

  • Frequency resolution: 1 Hz

  • Frequency accuracy: ± 7.0 ppm (1 year calibration interval, 18 °C to 28 °C)

  • Internal reference: 10 MHz at ±10 Hz accuracy, ±0.9 ppm/year aging

  • External reference input: 10 MHz ± 50 Hz Measurement Performance

  • System dynamic range: 125 dB (200 MHz–3 GHz), 122 dB (3 GHz–6 GHz)

  • Trace noise: Less than 0.008 dB RMS (typical 0.006 dB RMS)

  • IF bandwidth: 1 Hz to 500 kHz

  • Temperature stability: 0.008 dB/°C (300 kHz–3 GHz), 0.015 dB/°C (3 GHz–6 GHz) RF Ports & Power

  • 2-port configuration, Type-N Female connectors, 50 ohm impedance

  • Source power output: -50 dBm to +7 dBm

  • Settable level: -50 dBm to +10 dBm

  • Integrated bias tee on both ports: 0 to ±24 V, 0 to 200 mA Data & Display

  • Up to 20,001 measurement points per trace

  • 16 simultaneous traces with 9 marker positions


Key Features



  • USB 2.0 connectivity with VectorVu-PC™ software for Windows 7 or greater (64-bit)

  • SCPI command compatibility and LabView driver support for automation

  • Offline simulation mode for S-parameter file analysis without hardware

  • Touchstone file import/export for EDA tool integration

  • Low power consumption: 13 watts

  • Compact form factor: 285.8 mm × 206.4 mm × 44.5 mm (1.6 kg)


Typical Applications



  • S-parameter characterization of passive and active RF components

  • Cable and transmission line loss measurement

  • Antenna impedance and return loss testing

  • Filter and amplifier validation

  • Educational laboratory and production testing


Compatibility & Integration VectorVu-PC software provides direct instrument control and real-time analysis on Windows platforms. SCPI command set enables integration with automated test systems. Touchstone file support facilitates simulation workflow integration with industry-standard EDA tools.

Specifications

ParameterValue
Frequency Range100 kHz to 6 GHz | Power Range (dBm): '-50 dBm to +10 dBm settable, -50 dBm to +7 dBm output | Voltage / Current Range: 0 to ±24 V, 0 to 200 mA

Tektronix TTR506A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Tektronix TTR506A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Tektronix TTR506A price

This Tektronix TTR506A is listed at $5,570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Tektronix TTR506A calibration cost

NIST-traceable calibration for the Tektronix TTR506A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →