DynamicSignals / Kinetic Systems V266-ZA11 32-channel, 16-bit D/A Converter
DynamicSignals / Kinetic Systems VXI Modules. Channels: ** 32 independent analog output channels, Resolution: ** 16-bit.
- Model
- DynamicSignals / Kinetic Systems V266-ZA11
- Calibration
- Available on request
- Price
- $2,400
- Status
- In stock
- RFQ ref
- V266-ZA11
This unit
The DynamicSignals/Kinetic Systems V266-ZA11 is a 32-channel, 16-bit Digital-to-Analog converter engineered for precision analog signal generation in VXIbus systems. This single-width, C-size module delivers ±10 V full-scale outputs across 32 independent channels, making it suitable for industrial control, automated test equipment, and scientific research applications demanding high-resolution voltage outputs.
Technical Specifications
Channels: 32 independent analog output channels
Resolution: 16-bit
Output Range: ±10 V full-scale
Output Type: Analog voltage
Form Factor: Single-width, C-size VXIbus module
Data Interface: Dual-port memory accessed via A24/A16 address space with D16 data transfers
Memory: 16-bit wide dual-port memory for data values
Connectors: High-density front-panel connectors
Ground Configuration: Paired output signals to eliminate ground offset effects
Adjustments: Single gain and offset adjustments
Drift Characteristics: Low drift
Key Features
Register-based VXIbus architecture enabling static and dynamic configuration
Paired output signal design eliminates ground offset effects for improved accuracy
Low-drift performance maintains signal fidelity over extended operation
Single gain and offset adjustment capability simplifies calibration
Dual-port memory architecture supports efficient host processor communication
Typical Applications
Industrial automation and process control systems
Automated test equipment (ATE) requiring multi-channel signal generation
Scientific instrumentation and research platforms
Signal simulation and waveform generation in laboratory environments
Compatibility & Integration Designed as a VXIbus-compliant module, the V266-ZA11 integrates directly into existing VXIbus systems through standard C-size slot architecture. Memory-mapped access via A24/A16 address space and D16 data transfers ensure compatibility with standard VXIbus controllers and acquisition systems. Manufactured in the USA since 1968, DynamicSignals/Kinetic Systems delivers proven reliability in demanding test and measurement environments.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | ±10 V |
DynamicSignals / Kinetic Systems V266-ZA11 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the DynamicSignals / Kinetic Systems V266-ZA11. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common DynamicSignals / Kinetic Systems V266-ZA11 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
DynamicSignals / Kinetic Systems V266-ZA11 price
This DynamicSignals / Kinetic Systems V266-ZA11 is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
DynamicSignals / Kinetic Systems V266-ZA11 calibration cost
NIST-traceable calibration for the DynamicSignals / Kinetic Systems V266-ZA11 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →