Abaco Systems / VMIC VMIVME-1181-000 32-Channel P2 Input Board with Change-of-State
32-Channel P2 Input Board with Change-of-State
- Model
- Abaco Systems / VMIC VMIVME-1181-000
- Calibration
- Available on request
- Price
- $5,499
- Status
- In stock
- RFQ ref
- VMIVME-1181-000
This unit
The Abaco Systems / VMIC VMIVME-1181-000 is a 32-channel digital input board with programmable Change-of-State (COS) interrupt capabilities for VMEbus systems. The board captures state transitions on its input channels and generates interrupts based on user-defined conditions, enabling real-time event monitoring and response in applications. A 512-event FIFO buffer preserves state-change data during interrupt servicing, eliminating data loss in high-activity environments.
Technical Specifications
Digital Input- 32 channels via P2 high-reliability DIN connector
- Input impedance: 33 kΩ
- Threshold accuracy: ±10% over 1.25 V to 66 V input range
- User-selectable voltage thresholds: 1.25 V to 66 V Change-of-State Interrupt Logic
- Programmable via Control and Status Register (CSR)
- Selectable trigger modes: no interrupts, falling edge only, rising edge only, any transition
- Event buffer capacity: 512 state changes (FIFO) Input Conditioning
- Jumper-selectable debounce times: 10 µs, 1 ms, 5 ms, 10 ms
- Contact bounce elimination on make and break
- Transient suppression for ground noise and crosstalk
- Per-octet (8-channel group) input mode selection: contact closure, voltage source, or current sinking
- Open-circuit programmable to logic "0" or logic "1" VMEbus Interface
- VMEbus Rev. C.1 compliant
- Address range: A24:A16
- Data width: D32:D16:D08 (EO) with 8-, 16-, or 32-bit transfer support
- Slave address: DTB 39, 3D
- Interrupt vector: D08 (ROAK)
- COS data port: D0B(0) Built-In Diagnostics
- On-board BIT logic for fault isolation
- Front panel fail LED indicator Form Factor
- Double Eurocard (6U)
Key Features
- Flexible edge-triggered or level-based interrupt selection
- High input impedance minimizes loading on source circuits
- Wide voltage threshold range accommodates multiple signal types
- Debounce filtering eliminates contact chatter and electrical noise
- FIFO-based event capture prevents data loss in interrupt-heavy scenarios
Typical Applications
- Industrial process monitoring and discrete I/O control
- Safety-critical systems requiring deterministic event response
- Real-time data acquisition with transient detection
- Legacy VMEbus system modernization and expansion
Compatibility & Integration Designed for direct integration into VMEbus Rev. C.1 systems. Supports standard 16-bit and 32-bit data bus architectures. Jumper configuration enables field customization without firmware modification.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 1.25 V to 66 V |