Astronics / C&H Technologies VX405C M/MA Module Carrier

The VX405C M/MA Module Carrier from Astronics / C&H Technologies is designed to securely house and transport electronic modules. This carrier ensures the safe handling and protection of sensitive components during maintenance, testing, and integration processes. Its solid construction and precise design make it an ideal solution for demanding aerospace and industrial applications.

Model
Astronics / C&H Technologies VX405C
Calibration
Available on request
Price
$1,400
Status
In stock
RFQ ref
VX405C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Astronics / C&H Technologies VX405C M/MA Module Carrier is a VXIbus-resident carrier that provides mechanical and electrical interfacing for up to six VITA 12-1996 standard M/MA modules within a single VXI slot. The carrier manages VXI register configuration and delivers independent I/O space and memory access to each installed module, with individual logical addressing enabling flexible instrument integration. Each M/MA module operates as a distinct logical address within the VXI environment, supporting custom UUT interfacing through a library of over 200 available modules.

Technical Specifications

Module Capacity: Accommodates up to six (6) single-wide M or MA modules

Addressing: VXI A16, A24, and A32 addressing; D8, D16, and D32 data accesses

Data Access Time: <800 ns for M/MA modules

Module Functions: Extended M-Module Functions (MA) supported

EMI Shielding: Front panel EMI shielding integrated

Physical Dimensions (VXIbus Rev. 1.4 compliant, single slot 'C' size):

Height: 233.35 mm (9.187 in)

Depth: 340 mm (13.386 in)

Operating Temperature: 0°C to +55°C

Storage Temperature: -40°C to +75°C

Humidity: <95% without condensation

Key Features

Individual logical addressing for each installed M/MA module enables independent control and access

VXI register management for simplified integration and configuration

Fast data access (<800 ns) supports demanding test and measurement operations

Front panel EMI shielding maintains signal integrity in RF-sensitive environments

Supports extended M-module functionality for advanced instrumentation requirements

Typical Applications

Multi-instrument VXI test systems requiring compact slot utilization

Custom interface development for Units Under Test (UUT) via M/MA module selection

Distributed measurement and embedded test configurations

Compatibility & Integration Designed for VITA 12-1996 standard M/MA modules and full VXIbus system integration. Mechanical form factor conforms to VXIbus specification Rev. 1.4.

Astronics / C&amp;H Technologies VX405C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Astronics / C&amp;H Technologies VX405C. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Astronics / C&amp;H Technologies VX405C faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Astronics / C&amp;H Technologies VX405C price

This Astronics / C&amp;H Technologies VX405C is listed at $1,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Astronics / C&amp;H Technologies VX405C calibration cost

NIST-traceable calibration for the Astronics / C&amp;H Technologies VX405C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →