Fluke 1587/MDT FC-NIST Advanced Motor and Drive Troubleshooting Kit
Fluke Industrial Test Equipment. Voltage: 50 V, Frequency range: 15–400 Hz.
- Model
- Fluke 1587/MDT FC-NIST
- Calibration
- Available on request
- Price
- $1,760
- Status
- In stock
- RFQ ref
- 1587/MDT FC-NIST
This unit
The Fluke 1587/MDT FC-NIST Advanced Motor and Drive Troubleshooting Kit delivers integrated motor and drive diagnostics in a single handheld platform. It combines true-RMS digital multimeter functionality with insulation testing up to 1000 V, eliminating the need for separate instruments on the bench. The kit includes a current clamp rated to 400 A AC and a phase rotation indicator for three-phase system analysis, making it essential for predictive maintenance and field troubleshooting of industrial motor systems.
Technical Specifications
Fluke 1587 FC Insulation Multimeter- Insulation test voltage: 50 V, 100 V, 250 V, 500 V, 1000 V
- Insulation resistance range: 0.01 MΩ to 2 GΩ
- Resistance measurement: 0.1 Ω to 50 MΩ
- Safety rating: CAT III 1000 V, CAT IV 600 V
- Live circuit detection: Inhibits test above 30 V terminal voltage
- Capacitive load rating: Up to 1 μF
- PI/DAR timed ratio tests with TrendIt™ graphing
- VFD low-pass filter for drive measurements
- Auto-discharge of capacitive voltage Multimeter Functions
- AC/DC voltage, DC millivolts, AC/DC milliamps
- Continuity, capacitance, diode test
- Temperature and frequency (Hz) measurement
- Min/Max recording Fluke i400 AC Current Clamp
- Range: 1 A to 400 A AC
- Output: 1 mA per amp
- Maximum conductor diameter: 32 mm
- Non-intrusive circuit measurement
- Safety rating: CAT IV 600 V / CAT III 1000 V Fluke 9040 Phase Rotation Indicator
- Voltage range: 40–700 V
- Frequency range: 15–400 Hz
- Three-phase and sequence indication
Key Features
- TrendIt™ graphs identify moisture and contaminated insulation via PI/DAR analysis
- Fluke Connect™ app enables wireless data logging, historical tracking, and cloud sharing
- Auto power-off preserves battery life
- Large backlit display
- Traceable NIST calibration certificate included
Typical Applications
- Motor winding insulation integrity assessment
- Variable frequency drive diagnostics
- Three-phase system phase sequence verification
- Condition-based maintenance trending
- Preventive troubleshooting before failures occur
Compatibility & Integration Fluke Connect™ app support enables smartphone/tablet data capture, temperature compensation, and remote measurement sharing for distributed teams and centralized asset tracking.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 15–400 Hz | Voltage / Current Range: 50–1000 V insulation test |
Fluke 1587/MDT FC-NIST — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 1587/MDT FC-NIST. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 1587/MDT FC-NIST faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 1587/MDT FC-NIST price
This Fluke 1587/MDT FC-NIST is listed at $1,760. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 1587/MDT FC-NIST calibration cost
NIST-traceable calibration for the Fluke 1587/MDT FC-NIST is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →