Keithley 174

Keithley Laboratory Measurement Instruments. Accuracy: 0.013%, Sensitivity: 0.1 microvolt, Voltage: AC/DC to 1000 V peak.

Model
Keithley 174
Calibration
Available on request
Price
$110
Status
In stock
RFQ ref
174
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 174 is a 30,000-count digital multimeter engineered for precision general-purpose measurements across AC/DC voltage, AC/DC current, and resistance. Delivering 0.013% basic DC accuracy with 0.1 microvolt DC voltage sensitivity, the instrument provides flexible ranging via manual, automatic, or remote modes. Input isolation reaches 10⁹Ω case-to-case, ensuring signal integrity in demanding measurement environments.

Technical Specifications Display & Accuracy

30,000-count display resolution

Basic DC accuracy: 0.013%

DC voltage sensitivity: 0.1 microvolt

Settling time: 1 second to within 1 count of final reading Input Characteristics

Input resistance: 11 MΩ on 200 mV, 2 V, and 20 V ranges; 10 MΩ on 200 V and 1000 V ranges

Input isolation: Greater than 1000 MΩ on 200 mV and 2 V ranges with all function buttons in the out position

Normal mode rejection ratio: Greater than 60 dB at 50 Hz and 60 Hz Measurement Capabilities

Voltage: AC/DC to 1000 V peak

Current: AC/DC measurements supported

Resistance: 200 Ω to 2 MΩ ranges with ±(0.05% + 1–2 counts) accuracy

Diode test: Junction voltage display to 2 V; +5 V open-circuit voltage

dB mode: ±(0.02 dB + 1 count) accuracy above –78 dBm; 0.01 dB resolution above 5% of range Safety & Protection

Maximum allowable input: 1000 V DC or peak AC (less than 10 seconds per minute on 200 mV and 2 V ranges; 300 V RMS continuous); 450 V DC or peak AC for resistance measurements

Fuse: 2 A, 250 V, 3AG, normal-blow (Keithley FU-13 or equivalent)

Key Features

Three ranging modes: manual, automatic, or remote control

Compact form factor: 89 mm H × 235 mm W × 275 mm D; 1.8 kg

Low power consumption: 12 VA

Optional 6-hour battery pack (Model 1758)

Operating Environment

Operating temperature: 0°C to 50°C

Operating humidity: Less than 80% RH to 35°C; derate 3% RH/°C from 35°C to 50°C

Line voltage: 105–125 V or 210–250 V, 50–60 Hz (90–110 V available)

Compatibility & Integration Optional interfaces expand measurement capability: Model 1722 Digital Interface, Model 1723 IEEE Interface, Model 1740 AC Option, Model 1744 Ohmmeter Option, and Model 1745 Ammeter Option. Standard shrouded test leads (Model 1751) included.

Specifications

ParameterValue
Frequency Range50-60 Hz | Power Range (dBm): dB mode: -78 dBm and above | Voltage / Current Range: AC/DC voltage to 1000 V

Keithley 174 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 174. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 174 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 174 price

This Keithley 174 is listed at $110. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 174 calibration cost

NIST-traceable calibration for the Keithley 174 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →