Fluke 175 True RMS Digital Multimeter
The Fluke 175 True RMS Digital Multimeter is a versatile tool for electricians and technicians. It measures AC/DC voltage and current, resistance, capacitance, frequency, and temperature. With True RMS accuracy, it ensures precise readings of non-linear signals. It features a large, backlit display for easy viewing in any environment and Min/Max/Average recording to capture signal variations. Safety rated CAT III 1000V/CAT IV 600V.
- Model
- Fluke 175
- Calibration
- Available on request
- Price
- $379
- Status
- In stock
- RFQ ref
- 175
This unit
The Fluke 175 is a True RMS digital multimeter engineered for field troubleshooting and bench measurement across industrial and electronic systems. It delivers accurate readings on sinusoidal and non-sinusoidal signals through True RMS AC measurement, spanning voltage, current, resistance, capacitance, frequency, continuity, and diode testing in a single instrument.
Technical Specifications Voltage Measurement
DC: 0.1 mV to 1000 V, ±(0.15% + 2) accuracy
AC (True RMS): 0.1 mV to 1000 V, ±(1.0% + 3) accuracy, 5% to 100% of range frequency response
Crest factor: ≤3 at full scale to 500 V, linearly decreasing to ≤1.5 at 1000 V Current Measurement
DC: 0.01 mA to 10.00 A (20.00 A overrange for 30 seconds), ±(1.0% + 3) accuracy
AC (True RMS): 0.01 mA to 10.00 A (20.00 A overrange for 30 seconds), ±(1.5% + 3) accuracy
Frequency response 5% to 100% of range; crest factor ≤3 at full scale to 500 V, ≤1.5 at 1000 V Resistance: 0.1 Ω to 50.00 MΩ, ±(0.9% + 1) accuracy Capacitance: 1 nF to 9999 µF, 1.2% accuracy up to 1000 µF in the 9999 µF range Frequency: 2 Hz to 50 kHz; 30 kHz specified in mA and A ranges. below 10 kHz in 600 mV AC, 60 mA AC, and 6 A AC ranges Continuity: Beeper guaranteed on 250 Ω; detects opens or shorts ≥250 µs Diode Test: 2.400 V range, < 1.5 V DC test voltage Display: 6000-count digital display (4 updates/second) with 33-segment analog bargraph (40 updates/second)
Key Features
Manual and automatic ranging
Display Hold and Auto Hold for stable reading capture
Min/Max/Average recording over time
Test Lead Alert - "LEAd" message when rotary switch moves to/from Amp positions
Closed-case calibration through front panel
Safety rating: CAT III 1000V, CAT IV 600V
Typical Applications Maintenance and diagnostic work on industrial control systems, power distribution, HVAC systems, and general electronics requiring True RMS measurement on non-linear loads.
Compatibility & Integration Standard banana jack inputs. Front-panel controls for all functions without external software or connectivity requirements.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 20 Hz to 100 kHz (AC measurement bands) |
| 300 kHz typical 3dB bandwidth | Voltage / Current Range | 1000V |
| AC Voltage | 2V, 10A, 10A |
| AC Current | 200µA, 200mA, 200V, 20mA, 20V, 2mA, 2V, 750V |
| DC Current | 200µA, DC Voltage: 200mV |
Fluke 175 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 175. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 175 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 175 price
This Fluke 175 is listed at $379. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 175 calibration cost
NIST-traceable calibration for the Fluke 175 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →