HP / Agilent 3465A 4 1/2 DIGIT DMM
The HP/Agilent 3465A is a 4 1/2 digit digital multimeter designed for general-purpose measurements. It features a bright LED display, selectable ranges for AC/DC voltage, AC/DC current, and resistance, and offers reliable performance for electronics testing and troubleshooting.
- Model
- HP / Agilent 3465A
- Calibration
- Available on request
- Price
- $108
- Status
- In stock
- RFQ ref
- 3465A
This unit
The HP/Agilent 3465A is a 4 1/2 digit digital multimeter designed for general-purpose bench and field measurements. It has five core measurement functions
DC voltage, AC voltage, DC current, AC current, and resistance - with a 4 1/2 digit LED display and 2.5 readings per second sample rate. The instrument delivers midrange DC accuracy of ±0.02% ± 1 digit and resolves down to 1 µV on the 20 mV DC voltage range.
Technical Specifications Voltage Measurement
DC Voltage: 10 mV, 100 mV, 1 V, 10 V, 100 V, 1000 V ranges with 100% overrange on all except 1000 V
AC Voltage: 100 mV, 1 V, 100 V, 1000 V ranges; maximum 500 VAC rms (800 V peak); accuracy ±(0.15% + 0.05% of reading); 100% overrange to 10 kHz, linear decrease to 0% at 20 kHz
Frequency Response: 40 Hz to 20 kHz Current Measurement
DC/AC Current: 200 µA to 2000 mA ranges Resistance Measurement
Ranges: 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2000 kΩ, 20 MΩ
Open-circuit voltage maximum 5 V on most sensitive range
Key Features
4 1/2 digit LED display with overload indicator
Dual power architecture: rechargeable NiCad batteries (standard) or four "D" type dry cell batteries (Option 002)
AC line operation: 86–127 V or 172–254 V, 48–66 Hz
Low battery voltage detection with automatic shutdown
BCD output interface for data accumulation and logic signal processing
Rugged construction for field durability
Typical Applications General-purpose electrical measurement, bench testing, field service diagnostics, and routine circuit characterization across voltage, current, and resistance parameters.
Compatibility & Integration The 3465A provides BCD output for integration with external data processing equipment. Operates on AC line power or portable battery sources; optional Model 82002A Battery Charger/AC Adapter supports dry cell battery operation.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 40 Hz to 20 kHz | Voltage / Current Range: 48–66 Hz, DC Voltage: 10 mV to 1000 V |
| AC Voltage | 100 mV to 1000 V (500 VAC rms max) |
| DC/AC Current | 200 µA to 2000 mA |
| AC Input | 86–127 V or 172–254 V |
HP / Agilent 3465A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3465A. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 3465A faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.
HP / Agilent 3465A price
This HP / Agilent 3465A is listed at $107.98. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 3465A calibration cost
NIST-traceable calibration for the HP / Agilent 3465A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →