BK Precision 2630 Spectrum Analyzer
BK Precision Laboratory Measurement Instruments. Frequency Range: ** 0.15 MHz to 1.05 GHz (1050 MHz), Frequency Range: ** Matches the spectrum analyzer's range, Dynamic Range: ** 80 dB (113 dB with attenuation).
- Model
- BK Precision 2630
- Calibration
- Available on request
- Price
- $1,100
- Status
- In stock
- RFQ ref
- 2630
This unit
The BK Precision 2630 is a spectrum analyzer with a built-in tracking generator, designed for RF signal analysis up to 1.05 GHz. This instrument is suitable for professionals in telecommunications, cable TV, and related industries, offering capabilities for pre-compliance testing, RF leakage investigation, system troubleshooting, and EMI diagnostics. It is particularly useful for locating emission "hot spots" on PCBs and cables when used with an optional near-field sniffer probe set.
Technical Specifications * Product Type: Spectrum Analyzer with Tracking Generator
- Manufacturer: BK Precision
- Model: 2630
- Frequency Range: 0.15 MHz to 1.05 GHz (1050 MHz)
- Tracking Generator Frequency Range: Matches the spectrum analyzer's range
- Dynamic Range: 80 dB (113 dB with attenuation)
- Resolution Bandwidth (RBW): 20 kHz and 400 kHz. In some specifications, 12.5 kHz and 250 kHz are also mentioned for models 2625/2630, and 1 Hz to 1 MHz for other models
- IF Bandwidth: 400 kHz and 20 kHz
- Frequency Display Resolution: 100 kHz
- Frequency Scanwidth: 100 kHz/division
- Frequency Stability: 150 kHz/hour
- Amplitude Range: -100 dBm to +13 dBm. Another specification indicates -110 dBm to +30 dBm
- Maximum Input: +20 dBm
- Reference Level: -27 dBm to +13 dBm (in 10 dB steps)
- Demodulator: AM & FM demodulator included
- Input Connector: BNC
- Output Attenuator (Tracking Generator): 0 to 40 dB (4 x 10 dB steps)
- Output Impedance: 50 Ω (BNC)
- Display: CRT, 6 inch, 8 x 10 division, internal graticule. Another source mentions a 7-inch color TFT LCD
- Trace Rotation: Adjustable on front panel
- Line Voltage: 115 / 230V ±10%, 50-60Hz
- Power Consumption: Approximately 27W
- Operating Ambient Temperature: +10°C to +40°C
- Safety: Safety Class I (IEC 1010-1)
- Weight: Approximately 15.4 lb (6 kg)
- Dimensions: 4.9 in. (125 mm) H x 11.2 in. (285mm) W x 15 in. (380 mm) D
Interfaces and Connectivity * Input/Output: BNC connectors
- Connectivity (for some models/versions): USB host, USB device, LAN, GPIB (optional)
Physical Characteristics * Display: 6-inch CRT
- Dimensions: 4.9 in. (H) x 11.2 in. (W) x 15 in. (D)
- Weight: Approximately 15.4 lb (6 kg)
Accessories * Supplied: Power Cord, Instruction Manual, Software (for model 2635)
- Optional: * Near Field "Sniffer" Probe Set, Model PR-261 (covers 10 kHz to 1000 MHz) * AT-21 Right Angle Telescoping Antenna, BNC Connector * PR-70 Active FET Probe * TE-26 50Ω Feedthru Termination * RM-26 19-inch Rackmount Adapter * ZTF-1 50Ω to 75Ω Adapter * LC-210A Carrying Case
Compatibility * The BK Precision 2630 works with professionals in the telecommunication communications industry.
- It is suitable for CATV/MATV system troubleshooting, cellular telephone/pocket pager testing, and EMI diagnostics.
- The optional PR-261 probe set allows for investigation of RF electromagnetic fields, pre-compliance testing, and locating emission "hot spots" on PCBs and cables. Why Choose Aumictech for BK Precision 2630? At Aumictech, we specialize in supplying high-end RF test and measurement equipment. Whether you need precise RF signal analysis, comprehensive troubleshooting capabilities, or reliable EMI diagnostic tools, our team ensures the BK Precision 2630 delivers maximum performance for your application.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 3.2 GHz | Power Range (dBm): −100 dBm to +13 dBm | Voltage / Current Range: ±30 V (inputs) |
BK Precision 2630 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the BK Precision 2630. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common BK Precision 2630 faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.
BK Precision 2630 price
This BK Precision 2630 is listed at $1,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
BK Precision 2630 calibration cost
NIST-traceable calibration for the BK Precision 2630 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →