Agilent/Keysight 3465B

Agilent / Keysight Laboratory Measurement Instruments. Voltage: Full-scale ranges from 20 mV to 1000 V, Voltage: 40 Hz to 20 kHz measurement capability., Current: Resolution to 10 nA..

Model
Agilent / Keysight 3465B
Calibration
Available on request
Price
$3,250
Status
In stock
RFQ ref
3465B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 3465B is a 4½-digit digital multimeter engineered for precise DC and AC measurements across benchtop and field environments. This manual-ranging instrument delivers midrange DC accuracy of ±0.02% ±1 digit, with autopolarity and autozero functionality standard. An optional touch-hold probe allows measurement retention for hands-free operation.


Technical Specifications

DC Voltage: Full-scale ranges from 20 mV to 1000 V; 20 mV range provides 1 µV resolution. Additional ranges: 100 mV, 1 V, 10 V, 100 V. AC Voltage: 40 Hz to 20 kHz measurement capability. DC Current: Resolution to 10 nA. AC Current: Resolution to 10 nA across supported ranges. Resistance: 200 Ω to 20 MΩ coverage with 10 mΩ maximum resolution. Ranges include 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2000 kΩ, and 20 MΩ. Open-circuit voltage limited to 5 V on the most sensitive ohms range, protecting semiconductor devices during test. Accuracy: ±0.02% ±1 digit at midrange DC.

Key Features



  • Manual ranging with autopolarity correction

  • Autozero for baseline offset elimination

  • Touch-hold probe compatibility for measurement retention

  • Compact streamlined plastic case with carrying handle

  • Multiple power options: rechargeable Nicad batteries with internal charger, alkaline D cells (≈60 hours continuous operation), AC line power, or external DC supply via calculator battery chargers


Typical Applications Field service and bench troubleshooting requiring stable, manual-controlled measurements. Low-voltage analog circuit characterization. Semiconductor device testing where limited ohms-range voltage is critical.


Compatibility & Integration This instrument operates independently without network or USB connectivity. The touch-hold probe accessory extends measurement workflow flexibility for single-handed operation in confined spaces.

Agilent / Keysight 3465B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 3465B. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 3465B faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Agilent / Keysight 3465B price

This Agilent / Keysight 3465B is listed at $3,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 3465B calibration cost

NIST-traceable calibration for the Agilent / Keysight 3465B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →