Fluke 6082A – Synthesized RF Signal Generator
The Fluke 6082A is a synthesized RF signal generator that delivers high-performance and reliability for a wide range of RF testing applications. It offers precise frequency control, versatile modulation capabilities, and a clean spectral output. Ideal for communication, aerospace, and defense industries.
- Model
- Fluke 6082A
- Calibration
- Available on request
- Price
- $3,400
- Status
- In stock
- RFQ ref
- 6082A
This unit
The Fluke 6082A is a synthesized RF signal generator engineered for RF testing across communication, aerospace, and defense applications. Operating from 100 kHz to 2112 MHz with 0.001 Hz resolution, it delivers output power from -140 dBm to +19 dBm (with overranging to +20 dBm) into a 50 Ω nominal impedance. The instrument combines exceptional spectral purity - phase noise of -131 dBc/Hz at 1 GHz (20 kHz offset) and non-harmonic spurious below -100 dBc - with versatile modulation. AM, FM, pulse, and phase modulation operate independently or combined, with FM deviation to 8 MHz across rates from 0 to 100 kHz. Pulse rise time is <15 ns typical, and the internal modulation oscillator provides coherence with the RF carrier. Linear and logarithmic frequency or amplitude sweeps operate over 1 ms to 1000 s with digital control. Output level accuracy ranges from ±1 dB (0.4–2112 MHz) to ±2 dB (0.1–0.4 MHz), with ±1 dB flatness at +10 dBm. A fixed 20 dB attenuator vernier delivers transient-free switching in 0.1 dB steps. The instrument supports FSK and ASK modulation types and includes IEEE-488 (GPIB) control with emulation modes for Fluke 6060/6070 compatibility.
Technical Specifications
Frequency Range: 100 kHz to 2112 MHz, 0.001 Hz resolution
Output Power: -140 dBm to +19 dBm (±1 dB accuracy, 0.4–2112 MHz); ±1 dB flatness
Output Impedance: 50 Ω nominal
Phase Noise: -131 dBc/Hz at 1 GHz (20 kHz offset)
Non-Harmonic Spurious: <-100 dBc below 1056 MHz; <-94 dBc above 1056 MHz
FM Deviation: Up to 8 MHz; FM rates 0–100 kHz
Pulse Rise Time: <15 ns typical (<7.5 ns typical); 80 dB on/off ratio
Modulation Bandwidth: 500 kHz
Sweep Range: 1 ms to 1000 s; linear or logarithmic
Attenuator: 20 dB vernier, 0.1 dB resolution, transient-free
Control Interface: IEEE-488 (GPIB)
Key Features
Combined AM, FM, pulse, and phase modulation for complex signal synthesis
Coherent internal modulation oscillator enabling RF-carrier-coherent pulse waveforms
FSK and ASK capability
Digital frequency and amplitude sweep with 4096 maximum steps
X-axis (0 to +10 V ±10%) and Z-axis (TTL) sweep outputs
Low 1.5 Hz residual FM
Typical Applications
RF receiver and transceiver testing
Modulation performance validation
Spectral purity and spurious measurement
Aerospace and defense signal simulation
Compatibility & Integration IEEE-488 (GPIB) standard interface with Fluke 6060/6070 software emulation modes.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz to 2112 MHz | Power Range (dBm): '-140 dBm to +19 dBm | Voltage / Current Range: 0 to +10 V ±10% (X-axis output) |
Fluke 6082A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 6082A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 6082A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Fluke 6082A price
This Fluke 6082A is listed at $3,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 6082A calibration cost
NIST-traceable calibration for the Fluke 6082A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →