Anritsu 69017B Ultra Low Noise Synthesized CW Generator, 0.01 – 8.4 GHz

Anritsu 69017B,"Ultra low noise CW generator covering 0.01 to 8.4 GHz, built for applications demanding superior signal purity and stability. Supports high-precision testing of RF modules and systems. Offers fine frequency steps, high dynamic range, and GPIB remote programmability, ensuring accuracy and flexibility in laboratory and field environments."

Model
Anritsu 69017B
Calibration
Available on request
Price
$3,930
Status
In stock
RFQ ref
69017B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69017B is an ultra-low noise synthesized CW (Continuous Wave) generator engineered for high-precision RF testing across 0.01 GHz to 8.4 GHz. It delivers exceptional signal purity and frequency stability, enabling accurate characterization of RF modules and systems. The instrument combines precise frequency control with wide dynamic range performance, making it suitable for laboratory and field measurement environments where phase noise and spurious suppression are critical.


Technical Specifications

Frequency Range: 0.01 GHz to 8.4 GHz Operation Mode: CW (Continuous Wave) only Dynamic Range: High dynamic range for sensitive component testing Phase Noise Performance: Ultra-low noise design optimized for demanding metrology applications

Key Features



  • Precision frequency control with wide tuning range

  • Ultra-low phase noise and spurious signal suppression

  • High dynamic range output capability

  • GPIB remote control interface for automated test system integration

  • Front-panel manual operation and display

  • Precision amplitude control for flexible output configuration


Typical Applications



  • RF module and system characterization

  • High-precision frequency reference testing

  • Receiver and filter evaluation in demanding measurement scenarios

  • Automated RF testing environments via GPIB control


Compatibility & Integration GPIB interface enables direct integration into automated measurement systems and provides remote programmability for unattended operation and data logging in production and laboratory settings.

Specifications

ParameterValue
Frequency Range0.01 GHz to 8.4 GHz

Anritsu 69017B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69017B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69017B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69017B price

This Anritsu 69017B is listed at $3,930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69017B calibration cost

NIST-traceable calibration for the Anritsu 69017B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents