HP / Agilent 83623B High Power Swept-Signal Generator, 0.01 – 20 GHz,+17 dBm calibrated output
HP / Agilent RF Signal Sources. Frequency range: 0.01 to 20 GHz, Power range: -20 dBm to maximum available power (adjustable via, Resolution: 1 kHz (standard).
- Model
- HP / Agilent 83623B
- Calibration
- Available on request
- Price
- $7,800
- Status
- In stock
- RFQ ref
- 83623B
This unit
The HP/Agilent 83623B is a synthesized swept-signal generator delivering calibrated output power of +17 dBm across 0.01 to 20 GHz. Built for precision signal generation in test and development environments, this instrument combines frequency accuracy with dynamic sweep capability and exceptional spectral purity. Its leveled output performance remains stable across temperature variations, while harmonic suppression and low phase noise support demanding measurement and simulation tasks across RF and microwave bands.
Technical Specifications Frequency & Output Power
Frequency range: 0.01 to 20 GHz
Calibrated output power: +17 dBm
Maximum leveled output power: +17 dBm
Output power range: -20 dBm to maximum available power (adjustable via step attenuator)
Minimum settable output power (with Option 001): -110 dBm
Leveled output stability: Less than 2 dB degradation over 35 °C to 55 °C temperature range
Frequency resolution: 1 kHz (standard); 1 Hz (Option 008) Signal Quality
Harmonics: Typically -50 dBc below 20 GHz; at least 25 dB below carrier from 2.0 to 20 GHz
Phase noise (SSB): <-80 dBc at 10 GHz, 10 kHz offset; -76 dBc typical at 20 GHz, 10 kHz offset
Spurious signals: Typically -60 dBc from 10 MHz to 80 dB on/off ratio; rise/fall times <10 ns (Option 006); 15 ns minimum pulse width; 5 ns timing accuracy
AM capability: 99.7% modulation depth (50 dB); 100 kHz bandwidth, DC-coupled
FM capability: ±8 MHz maximum deviation (locked); 8 MHz modulation rate, DC-coupled
Internal modulation generator (Option 002): Sine (1 Hz to 1 MHz), square/triangle/ramp (1 Hz to 100 kHz), noise waveforms; 0.1% depth/deviation resolution
Key Features
Synthesized architecture ensures frequency accuracy and stability across full operating range
Leveled output maintains consistent power delivery with minimal temperature sensitivity
Low phase noise supports precision measurement and dynamic testing applications
Multiple sweep modes enable flexible signal simulation and characterization
Optional attenuator extends dynamic range to -110 dBm
Typical Applications
Component and subsystem characterization from DC/RF to microwave frequencies
Receiver sensitivity and selectivity testing
Harmonic and intermodulation distortion analysis
Pulse and modulated signal generation for radar and communications testing
Frequency sweep and ramp modulation studies
Compatibility & Integration The 83623B operates as a standalone instrument with optional modules for extended functionality. Option 001 adds step attenuator capability; Option 002 integrates internal modulation waveform generation; Option 006 provides sub-10 ns pulse rise/fall times; Option 008 enables 1 Hz frequency resolution.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.01 to 20 GHz | Power Range (dBm): '-20 dBm to +17 dBm (standard) |
HP / Agilent 83623B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83623B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83623B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83623B price
This HP / Agilent 83623B is listed at $7,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83623B calibration cost
NIST-traceable calibration for the HP / Agilent 83623B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →