Fluke 87V/IMSK Industrial Multimeter Service Combo Kit with current clamp, 1000 V, 10 A

The Fluke 87V/IMSK Industrial Multimeter Service Combo Kit is a set for industrial troubleshooting. It includes the Fluke 87V digital multimeter, known for its accuracy and reliability, along with an i400 AC current clamp for measuring current up to 400 A without breaking the circuit. The kit also features TL75 Hard Point Test Lead Set, AC72 Alligator Clip Set and 80BK-A Thermocouple Probe. Designed for demanding environments, it offers true-RMS AC voltage and current measurements, a built-in thermometer, and Min/Max/Average recording.

Model
Fluke 87V/IMSK
Calibration
Available on request
Price
$570
Status
In stock
RFQ ref
87V/IMSK
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 87V/IMSK Industrial Multimeter Service Combo Kit delivers precision measurement capability for field troubleshooting and bench diagnostics in industrial electrical systems. The kit pairs the Fluke 87V True-RMS digital multimeter with the Fluke i400 AC current clamp, supported by essential accessories including the TL75 test lead set, AC72 alligator clip set, and 80BK-A thermocouple probe.

Technical Specifications Fluke 87V Industrial Multimeter

Voltage (DC): 1000 V max, ±(0.05% + 1) accuracy, 10 µV resolution

Voltage (AC): 1000 V max, ±(0.7% + 2) accuracy at 45–65 Hz, True-RMS with selectable low-pass filter for VFD environments

Current (DC/AC): 10 A continuous (20 A for 30 seconds), DC accuracy ±(0.2% + 2), AC accuracy ±(1.0% + 2) True-RMS

Resistance: 50 MΩ max

Capacitance: 10,000 µF max

Frequency: 200 kHz max with VFD-compatible filtering

Duty Cycle: 99.9% max, ±(0.2% per kHz + 0.1%) accuracy

Conductance: 60.00 nS max

Temperature: -200.0 to 1090°C (-328.0 to 1994.0°F) with external probe

Peak Capture: 250 µS response for intermittent fault detection

Display: 6,000 counts (19,999 in high-resolution mode), analog bar graph, dual-level backlight

Safety: CAT III 1000 V / CAT IV 600 V, >8000 V spike rated

Battery: 400 hours typical (backlight off)

Dimensions: 1.25 × 3.41 × 7.35 in Fluke i400 AC Current Clamp

Range: 1 A to 400 A AC continuous

Key Features

Non-intrusive AC current measurement to 400 A

True-RMS measurement engine for non-linear signal accuracy

Selectable low-pass filtering for adjustable-speed drive diagnostics

Peak capture for transient detection down to 250 µS

Temperature measurement capability via thermocouple probe

Audible input alert for jack configuration verification

High-resolution mode extends display to 19,999 counts

Typical Applications

Motor circuit troubleshooting and commissioning

VFD and variable speed drive diagnosis

HVAC/refrigeration system service

Electrical distribution and control panel diagnostics

Equipment performance validation in industrial plants

Compatibility & Integration The 87V multimeter accepts standard banana plugs and supports external thermocouple probes for extended temperature measurement range. The i400 clamp output connects to the millivolts input of compatible multimeters.

Specifications

ParameterValue
Frequency RangeDC to 200 kHz | Voltage / Current Range: 1–400 A AC (via clamp), 10 A continuous (20 A for 30 seconds), 1000 V DC/AC

Fluke 87V/IMSK — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 87V/IMSK. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 87V/IMSK faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 87V/IMSK price

This Fluke 87V/IMSK is listed at $570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 87V/IMSK calibration cost

NIST-traceable calibration for the Fluke 87V/IMSK is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents