Yokogawa AQ6370D 600-1700nm Optical Spectrum Analyzer

Yokogawa Optical Spectrum Analyzers. Accuracy: Standard Model (-10): ±0.02 nm (1520–1580 nm), Resolution: 0.001 nm, Accuracy: ±0.2 dB (C-band.

Model
Yokogawa AQ6370D
Calibration
Available on request
Price
$38,779
Status
In stock
RFQ ref
AQ6370D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Yokogawa AQ6370D Optical Spectrum Analyzer is a instrument designed for analyzing the spectral components of light. Covering the 600 to 1700 nm wavelength range, it is suitable for characterizing optical devices and systems in telecommunications, research, and manufacturing. Key features include high wavelength accuracy, resolution bandwidth settings, and a wide dynamic range, enabling precise measurement of optical signals. The AQ6370D supports various analysis functions, such as peak search, spectral width measurement, and optical power measurement. Its user-friendly interface and comprehensive software facilitate efficient data acquisition and analysis.  

Aumictech – Yokogawa AQ6370D 600–1700 nm Optical Spectrum Analyzer Specifications


Optical Performance



  • Wavelength range: 600 to 1700 nm



  • Span: 0.5 nm to 1100 nm (full span), and 0 nm



  • Wavelength accuracy:


    • Standard Model (-10): ±0.02 nm (1520–1580 nm), ±0.02 nm (1580–1620 nm), ±0.04 nm (1450–1520 nm), ±0.1 nm (full range)



    • Model (-20): ±0.01 nm (1520–1580 nm), ±0.02 nm (1580–1620 nm), ±0.04 nm (1450–1520 nm), ±0.1 nm (full range)





  • Wavelength repeatability: ±0.002 nm (typical, C-band)



  • Resolution bandwidth settings: 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2 nm



  • Minimum sampling resolution: 0.001 nm; 101 to 50,001 points




Level / Power



  • Sensitivity modes: NORM_AUTO, NORMAL, MID, HIGH1, HIGH2, HIGH3



  • Sensitivity (typical): −90 dBm (1300–1620 nm), −85 dBm (1000–1300 nm), −60 dBm (600–1000 nm)



  • Maximum input power: +20 dBm per channel, +25 dBm safe total



  • Level accuracy: ±0.2 dB (C-band, −20 dBm input)



  • Level linearity: ±0.02 dB (−50 to +10 dBm, C-band)



  • Level flatness: ±0.1 dB (1520–1580 nm), ±0.2 dB (1450–1520 nm, 1580–1620 nm)



  • Polarization dependence: ±0.02 dB (C-band)




Dynamic Range & Stray Light



  • Close-in dynamic range:


    • At 0.02 nm RBW: up to 60 dB (±0.2 nm)



    • At 0.05 nm RBW: up to 78 dB (±1.0 nm, typical)



    • At 0.1 nm RBW: up to 67 dB (±0.4 nm, typical)





  • Stray light suppression ratio: up to 80 dB (typical model)



  • Wide level range: +20 to −90 dBm




Sweep & Speed



  • Sweep times (100 nm span, typical):


    • NORM_AUTO: 0.2 s



    • NORMAL: 0.5–1 s



    • MID: 2 s



    • HIGH1: 5 s



    • HIGH2: 20 s



    • HIGH3: 75 s





  • High dynamic mode: available, reducing stray-light effects




Fiber & Optical Interfaces



  • Applicable fibers: Single-mode 9.5/125 µm, GI 50/125 µm, 62.5/125 µm



  • Optical input: AQ9447 connector adapter (FC/SC/ST)



  • Calibration output: AQ9441 universal adapter (FC/SC/ST)



  • Optical return loss: typically 35 dB (with APC connector)



  • Built-in wavelength reference source: included for calibration and alignment



  • APC level correction: supported




Interfaces & Control



  • Remote control: GP-IB, RS-232, Ethernet (SCPI compatible, AQ6317 emulation, LabVIEW driver)



  • I/O ports: GP-IB, RS-232, Ethernet (10/100Base-T), USB, PS/2 keyboard, SVGA output, trigger in/out




Display & Storage



  • Display: 10.4-inch color LCD, 1024×768 resolution



  • Internal storage: 512 MB; up to 64 traces and 64 programs



  • External storage: USB (FAT32), file formats: CSV, Binary, BMP, TIFF



  • Trace functions: up to 7 simultaneous traces, subtraction, Max/Min hold, All-at-Once save



  • Printer option: built-in thermal printer available




Physical & Power



  • Dimensions: 426 × 221 × 459 mm (W×H×D, without protector/handle)



  • Weight: approx. 19 kg (without printer)



  • Power supply: 100–240 VAC, 50/60 Hz, ~150 VA



  • Operating conditions:


    • Performance guarantee: +18 to +28 °C



    • Operating: +5 to +35 °C



    • Storage: −10 to +50 °C



    • Humidity: ≤ 80 %RH (non-condensing)





  • Warm-up time: 1 hour minimum




Models & Options


  • Models: AQ6370D-10 (Standard), AQ6370D-20 (High-performance)



  • Connector adapters: AQ9447 (FC/SC/ST), AQ9441 universal adapter (FC/SC/ST)



  • Options: /B5 thermal printer




Why Choose Aumictech for the Yokogawa AQ6370D?


The Yokogawa AQ6370D 600–1700 nm Optical Spectrum Analyzer represents one of the most advanced OSAs available, with accuracy, high dynamic range, and fast sweep speed. At Aumictech, we supply, calibrate, and repair the AQ6370D for manufacturers, research labs, and telecom providers who require precision and reliability. Our calibration is NIST-traceable, ensuring the AQ6370D performs at its peak across its full wavelength range.

Frequently Asked Questions

What does the Yokogawa AQ6370D measure and what is its wavelength range?
The AQ6370D is a high-precision optical spectrum analyzer that measures optical power across the 600–1700 nm wavelength range, covering visible through near-infrared spectrum. It delivers 0.001 nm spectral resolution and wavelength accuracy of ±0.02 nm in the 1520–1580 nm C-band window, with power measurement accuracy of ±0.2 dB in C-band. This instrument is ideal for telecom component testing, fiber characterization, and broadband light source analysis.
What condition is this Yokogawa AQ6370D in, and what has been verified?
We have thoroughly inspected this used AQ6370D unit and verified its core optical measurement functions and mechanical condition prior to listing. All display, keypad, and connector interfaces have been tested for proper operation. We recommend a full calibration recertification to ensure measurement traceability to NIST standards; calibration is available separately starting at $450.
What does calibration cover for the AQ6370D, and what is the cost and turnaround?
Calibration for the AQ6370D includes wavelength accuracy verification across key bands and optical power measurement linearity checks, ensuring the instrument meets Yokogawa's published specifications. Our calibration service starts at $450 and is available separately; specific turnaround times and scope details can be provided upon request. We recommend recalibration if the unit has not been serviced within the past two years or if traceability is required for compliance.
What are the connectivity and interface options on the AQ6370D?
The AQ6370D features GPIB (IEEE 488) and RS-232 interfaces for remote instrument control and data logging integration with laboratory automation systems. Compatible software drivers and command sets are available through Yokogawa; we can provide guidance on legacy software compatibility and modern alternatives for data acquisition. USB connectivity may be available through optional adapters depending on your system architecture requirements.

Yokogawa AQ6370D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ6370D. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Yokogawa AQ6370D faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Yokogawa AQ6370D price

This Yokogawa AQ6370D is listed at $38,779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Yokogawa AQ6370D calibration cost

NIST-traceable calibration for the Yokogawa AQ6370D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents