Keithley DMM6500 6.5 Digit Multimeter with Graphical Touchscreen
Keithley Laboratory Measurement Instruments. Voltage: 0.1 µV to 1010 V, Voltage: Up to 750 V, Current: 10 pA to 10.1 A.
- Model
- Keithley DMM6500
- Calibration
- Available on request
- Price
- $1,770
- Status
- In stock
- RFQ ref
- DMM6500
This unit
The Keithley DMM6500 is a 6.5-digit bench and system multimeter engineered for precision measurement across research, development, manufacturing, and laboratory environments. Its 5-inch capacitive touchscreen delivers a graphical interface with pinch-and-zoom capability for intuitive data visualization. The instrument integrates 15 measurement functions
DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, temperature (RTD, thermistor, thermocouple), diode test, and digitizing - enabling comprehensive electrical characterization without external instrumentation. sits a 16-bit digitizer operating from 1 kS/s to 1 MS/s, storing up to 7,000,000 readings for transient capture and analysis.
The DMM6500 delivers measurement rates to 21,000 readings per second with a minimum measurement time of 8.3 µs (10 µs at 50 Hz). DC voltage accuracy reaches 25 PPM (0.0025%) over one year and 30 PPM over two years.
Technical Specifications
Measurement Ranges- DC Voltage: 0.1 µV to 1010 V
- AC Voltage: Up to 750 V
- DC Current: 10 pA to 10.1 A
- AC Current: Up to 10 A
- Resistance: 1 µΩ to 120 GΩ
- Capacitance: 0.1 pF to 120 µF
- Temperature: RTD, thermistor, thermocouple
- Digitizer: 16-bit, 1 kS/s to 1 MS/s, 7,000,000 reading memory Display & Interface
- 5-inch multi-touch capacitive touchscreen, 800 × 480 resolution
- USB-TMC, LXI/Ethernet standard; optional GPIB, TSP-Link, RS-232
Key Features
- 6.5-digit resolution with 0.0025% basic DC voltage accuracy
- 1 MS/s, 16-bit digitizer for voltage and current transients
- Measurement rate: Up to 21,000 readings/second
- Scanner card slot supporting up to 10 switching channels (2-pole) or 5 channels (4-pole)
- Optional 2001-TCSCAN for 9-channel temperature scanning
- Graphical touchscreen with pinch-and-zoom data interaction
System Integration & Programming Multiple programming modes accommodate existing test environments: SCPI (default), Keithley 2000 SCPI emulation, Keysight 34401A SCPI emulation, and TSP scripting. Driver support includes LabVIEW, IVI-C, IVI-COM, Keithley Test Script Builder, and KickStart software.
Typical Applications R&D characterization, manufacturing test, bench measurement, system integration with multi-channel switching and temperature monitoring, and transient analysis requiring high-speed digitization.
Keithley DMM6500 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley DMM6500. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keithley DMM6500 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Keithley DMM6500 price
This Keithley DMM6500 is listed at $1,770. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley DMM6500 calibration cost
NIST-traceable calibration for the Keithley DMM6500 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →