Agilent / Keysight E1410A 6.5-Digit Multimeter High-Accuracy, C-Size

The Agilent/Keysight E1410A is a high-accuracy, C-size, 6.5-digit multimeter designed for VXIbus systems. It offers precise measurements and reliable performance for demanding applications.

Model
Agilent / Keysight E1410A
Calibration
Available on request
Price
$2,246
Status
In stock
RFQ ref
E1410A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight E1410A is a 6.5-digit multimeter module designed for VXIbus systems. This C-size, single-slot message-based VXI device delivers high-accuracy measurements with resolution and speed optimizable for demanding laboratory and system integration applications. Engineers and test professionals rely on the E1410A for precise DC voltage, AC voltage, resistance, and temperature measurements across demanding measurement environments.


Technical Specifications



  • Resolution: 6.5 digits

  • Measurement Speed: Over 1,450 readings per second in both 3.5-digit and 6.5-digit normal mode

  • DC Voltage Range: Up to 300.0 V

  • AC Voltage: True RMS measurements from 20 Hz to 1 MHz

  • Resistance Measurement: 2- and 4-wire modes with offset compensated ohms

  • Temperature Support: Thermistor and RTD measurements

  • Integration Time: Selectable from 100 power line cycles to 0.0005 power line cycles

  • Noise Rejection: Normal mode rejection up to 90 dB in 6.5-digit mode; high common mode rejection

  • Calibration: Software calibration supported


Key Features



  • Offset compensated ohms eliminate series voltage offsets for precise resistance measurement

  • Programmable settling times optimize AC measurement performance

  • Long integration times and system guard enable accurate low-level signal measurements

  • Extensive external triggering with TTL trigger lines accessible from front panel or VXIbus

  • External trigger and voltmeter complete signals support system synchronization

  • Configurable resolution, accuracy, and noise rejection parameters for speed-accuracy optimization


Typical Applications Component and subsystem characterization, automated test systems, precision data acquisition, low-level signal measurement, multipoint temperature monitoring, and resistance verification in laboratory and production environments.


Compatibility & Integration Designed as a message-based VXI device, the E1410A integrates directly into VXIbus systems. C-size, 1-slot form factor enables compact system configurations while maintaining full measurement capability and control via the VXIbus.

Specifications

ParameterValue
Frequency Range20 Hz to 1 MHz | Voltage / Current Range: 0–300.0 V DC

Agilent / Keysight E1410A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E1410A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight E1410A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Agilent / Keysight E1410A price

This Agilent / Keysight E1410A is listed at $2,246.38. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight E1410A calibration cost

NIST-traceable calibration for the Agilent / Keysight E1410A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →