Agilent / Keysight E1459A 64-Channel VXI Isolated Digital Input
The Agilent/Keysight E1459A is a 64-channel VXI isolated digital input module. It provides isolated digital inputs for data acquisition and control applications in VXI systems. The module offers high-density input channels and isolation to protect the VXI system from external voltage sources.
- Model
- Agilent / Keysight E1459A
- Calibration
- Available on request
- Price
- $320
- Status
- In stock
- RFQ ref
- E1459A
This unit
The Keysight E1459A is a 64-channel VXI isolated digital input module for DC level and edge transition sensing up to 48 Vdc in register-based VXI systems. Optical isolation on all inputs protects against transients up to 125 Vrms or Vdc between channels or to chassis, safeguarding the system from external voltage sources. The module occupies a single C-size slot and operates as a slave device with selectable interrupt levels 1–7.
Technical Specifications
Input Characteristics- 64 isolated digital input channels
- Sensing range: DC levels and edge transitions to 48 Vdc
- Maximum input voltage: 60 Vdc (between high and low terminals per channel); 125 Vrms or Vdc (between channels or to chassis)
- Nominal input voltages: 5, 12, 24, and 48 Vdc
- Threshold voltages: 1–4 Vdc (5 V nominal), 2.5–9.5 Vdc (12 V nominal), 7–17 Vdc (24 V nominal), 14–31 Vdc (48 V nominal)
- Input current: 0.5, 1.3, 2.8, or 5.8 mA at nominal voltages
- Minimum input pulse width: 100 ms plus debounce time
- On-board 5 V supply: 4.5–5.5 Vdc output, 16 mA maximum output current
- TTL-compatible logic levels, 5 V maximum Debounce & Data Transfer
- Programmable debounce: 16 µs to 1074 s in binary increments
- Separate debounce periods for channel groups 1–32 and 33–64
- 16-bit word structure with strobe-in, ready-for-data, and interrupt-out per word
- Parallel strobe-in connection for 32- or 64-bit transfers
- VXI register access with D16 interface capability
Key Features
- Optical isolation protects VXI systems from external voltage transients
- Programmable debounce with independent group settings reduces noise sensitivity
- On-board 5 V supply with 9.4 kΩ effective pull-up for switch-state detection
- Flexible data transfer via strobe-in parallel connection
- Interrupter capability with selectable interrupt levels
Typical Applications
- Industrial control systems requiring galvanic isolation
- Multi-channel digital acquisition from isolated sensor networks
- Safety-critical systems with voltage transient protection
- VXI test and measurement systems with mixed-voltage inputs
Compatibility & Integration VXI register-based slave module; A16 addressing; D16 bus interface. Compatible with standard VXI chassis and controllers supporting interrupt-capable modules.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 12 Vdc, 24 VDC, 48 Vdc input |
Agilent / Keysight E1459A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E1459A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight E1459A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Agilent / Keysight E1459A price
This Agilent / Keysight E1459A is listed at $320.2. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight E1459A calibration cost
NIST-traceable calibration for the Agilent / Keysight E1459A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →