Agilent / Keysight E1465A 16 x 16 Relay Matrix Switch

The Agilent/Keysight E1465A is a 16x16 Relay Matrix Switch, designed for signal routing and switching applications. It features a matrix configuration with 16 rows and 16 columns, providing a total of 256 crosspoints. This module is suitable for automated testing, signal monitoring, and data acquisition systems.

Model
Agilent / Keysight E1465A
Calibration
Available on request
Price
$1,065
Status
In stock
RFQ ref
E1465A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight E1465A is a C-size VXI relay matrix switch module delivering 256 crosspoints in a compact 16×16 two-wire configuration. Engineered for automated test, signal routing, and data acquisition, this register-based module handles voltages to 200 Vdc or 170 Vacrms, with per-channel current ratings of 1 A and maximum power dissipation of 30 W per channel. The latching armature relay design ensures low on-resistance - less than 4.0 Ω worst-case and under 1.8 Ω best-case at initial contact, degrading to under 10.0 Ω end-of-life.


Insulation resistance exceeds 10⁸ Ω under humid conditions and 10⁹ Ω at standard lab conditions.


Technical Specifications



  • Switching Matrix: 16×16 two-wire relay matrix, 256 total crosspoints

  • Voltage Rating: 200 Vdc or 170 Vacrms (238 Vac peak-to-peak)

  • Current per Channel: 1 Adc or 1 A ac peak (non-inductive)

  • Power per Channel: 30 Wdc maximum; 62.5 VA module maximum (resistive load)

  • Closed Channel Resistance: < 4.0 Ω worst-case initial; < 1.8 Ω best-case initial; 10⁸ Ω (40°C, 95% RH); > 10⁹ Ω (25°C, 40% RH)

  • Thermal Offset: 10 MHz (worst crosspoint, –3 dB)

  • Closed Channel Capacitance: < 270 pF (Hi-Low); < 430 pF (Hi-Ground); < 440 pF (Lo-Ground)

  • Crosstalk Within Card (worst path, typical): –66 dB <10 kHz; –45 dB <100 kHz; –29 dB <1 MHz

  • Relay Life: 10⁷ operations (no load); 5 × 10⁷ operations (no load)


Key Features



  • Latching armature relays for power efficiency

  • QUIC easy-to-use terminal blocks; interchangeable blocks enable topology reconfiguration

  • Scalable architecture supporting row and column expansion via chaining cables

  • Compatible with E1466A and E1467A modules for larger matrix configurations


Typical Applications



  • Automated test equipment (ATE) signal routing

  • Multi-channel data acquisition and signal monitoring

  • Precision low-level switching in measurement systems


Compatibility & Integration



  • Four E1465A modules interconnected create a 32×32 matrix (1024 crosspoints)

  • Full E1401B 13-slot mainframe accommodates up to 3072 two-wire crosspoints across multiple modules

  • VXIbus C-size, register-based control

Specifications

ParameterValue
Voltage / Current Range1 A, 200 V

Agilent / Keysight E1465A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E1465A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight E1465A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Agilent / Keysight E1465A price

This Agilent / Keysight E1465A is listed at $1,065.4. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight E1465A calibration cost

NIST-traceable calibration for the Agilent / Keysight E1465A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents