This unit
The Keysight E8462A is a C-size, 1-slot VXI multiplexer module built on non-latching armature relays for high-density signal routing in automated test and data acquisition systems. With 256 channels and eight programmable switching topologies, it accommodates two-wire, three-wire, and four-wire measurement configurations. Register-based control enables flexible, reconfigurable signal paths across diverse circuit topologies.
Technical Specifications Switching Architecture
256 total channels across eight configurable topologies: one 256 × 1, four 64 × 1, one 128 × 2, two 32 × 4, one 64 × 3, eight 32 × 1
Non-latching armature relays with 5 ms maximum open/close time
Maximum switching current: 2 A @ 30 V
Rated full resistive load: 60 VA Electrical Ratings
DC voltage: 250 V (Option 012), 60 V (Options 014/015)
AC peak voltage: 350 V (Option 012), 70.7 V (Options 014/015)
Power dissipation: 10 W typical, 30 W maximum per slot
Current draw: +5 V at 1.0 A typical Environmental & Physical
Operating temperature: 0°C to 55°C
Storage temperature: 0°C to 40°C
Operating humidity: 65% RH (0°C to 40°C)
IEC 664 Pollution Degree 2
Key Features
Eight independent switching topologies support varied measurement configurations without hardware reconfiguration
Terminal block options (sold separately) provide voltage and protection flexibility across three connector variants
Included 2.5-in. analog bus cable (E1400-61605) enables direct slot-adjacent module integration
Register-based control simplifies programmable routing within VXIbus systems
Typical Applications Automated test systems requiring multi-channel signal distribution, resistance measurement networks, temperature sensor multiplexing, and multi-point data acquisition with configurable measurement topologies.
Compatibility & Integration Register-based VXI module designed for E1400-series VXIbus systems. Direct compatibility with E1411B multimeter modules via included analog bus cable. Terminal block integration requires separate procurement of appropriate Option 012, 014, or 015 terminal card.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0-250 V DC (Option 012), 0-60 V DC (Options 014/015) |
Keysight / Agilent / HP E8462A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent / HP E8462A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keysight / Agilent / HP E8462A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Keysight / Agilent / HP E8462A price
This Keysight / Agilent / HP E8462A is listed at $3,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keysight / Agilent / HP E8462A calibration cost
NIST-traceable calibration for the Keysight / Agilent / HP E8462A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →